期刊论文详细信息
Micro & nano letters
Glucose biosensor using fluorescence quenching with chitosan-modified graphene oxide
article
Wenjun Li1  Tingting Jiang2  Yang Pu3  Xudong Jiao1  Wenqiang Tan1  Song Qin1 
[1]Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences
[2]School of Life Science, Ludong University
[3]School of Agriculture, Ludong University
关键词: biochemistry;    biosensors;    nanosensors;    nanofabrication;    fluorescence;    molecular biophysics;    radiation quenching;    chemical sensors;    sugar;    proteins;    biomedical optical imaging;    graphene compounds;    GO-CS;    low concentrations;    competitive binding;    maltose-binding protein;    recombinant phycocyanin;    far-red fluorescence;    MBP-rPC;    rPC emission;    rPC fluorescence;    linear detection range;    glucose biosensor;    fluorescence quenching;    chitosan-modified graphene oxide;    low-molecular-weight chitosan;    glucose detection;    fluorescence resonance energy transfer;    graphene oxide nanomaterial;    mass 0.1 mg to 1.0 mg;    CO;   
DOI  :  10.1049/mnl.2018.5269
学科分类:计算机科学(综合)
来源: Wiley
PDF
【 摘 要 】
Metoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while electrode using DOP shows a linear concentration range between 3.0×10-5 – 1.0×10-2 M and detection limit 6×10-6 M. The selectivity coefficient values were calculated for MCP with respect to different inorganic cations, sugars and amino acids using the MCP depending on TBP plasticizer which is also used for the determination of MCP in pure solutions and in pharmaceutical preparations by direct, standard addition methods and as an indicator electrode in potentiometric titration with phosphotungstic acid (PT) giving satisfactory results.
【 授权许可】

CC BY|CC BY-ND|CC BY-NC|CC BY-NC-ND   

【 预 览 】
附件列表
Files Size Format View
RO202107100002881ZK.pdf 1609KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次