期刊论文详细信息
BMC Musculoskeletal Disorders
Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study
Conrad Anderl1  Martin Steinmair1  Josef Hochreiter1  Georg Mattiassich2  Reinhold Ortmaier3 
[1] Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria;Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria;Ludwig-Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstrasse 13, 1200, Vienna, Austria;Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria;Research Unit of Orthopedic Sports Medicine and Injury Prevention, Institute for Sports Medicine, Alpine Medicine and Health Tourism (ISAG), UMIT, Eduard-Wallnöfer-Zentrum 1, 6060, Hall in Tirol, Austria;
关键词: Total hip arthroplasty;    Monoblock cups;    Bone remodelling;    Elastic fixation;    Bone mineral density;    DEXA;   
DOI  :  10.1186/s12891-020-03675-7
来源: Springer
PDF
【 摘 要 】

BackgroundBone stock preservation in total hip replacement is essential to allow for later revisions in an increasingly younger and fitter index patient population. While contemporary modular press-fit acetabular cups lead to rigid fixation with equatorial stress and central osteolysis, more elastic fixation may cause different peri-acetabular bone remodelling. The purpose of this study was to investigate changes in peri-acetabular bone mineral density (BMD) in uncemented elastic fixation with monoblock press-fit cups.MethodsThis prospective observational study included 45 patients with monoblock cups. We evaluated peri-acetabular BMD using dual-energy X-ray absorptiometry and reported functional outcomes and complications.ResultsAt a mean follow-up of 24.2 ± 2.2 months, we found that BMD stabilised in DeLee and Charnley zones I and III and recovered to baseline value in zone II. The mean Harris Hip Scores improved significantly from 56.9 ± 20.0 to 97.2 ± 4.0 (p <  0001). Other than one peri-operative dislocation, we saw no post-operative complications.ConclusionsWe found favourable adaptive bone changes with BMD stabilisation in the equatorial zones and recovery to pre-operative values in the central zone. Additionally, excellent clinical outcomes and few prosthesis-related complications strengthened the favourable results of monoblock acetabular cups.Trial registrationRegistration number DRKS00017076.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202104266784032ZK.pdf 1005KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:1次