期刊论文详细信息
ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Ports minimization with mini-port and liver flexible retractor: an ergonomic and aesthetic alternative for single port in laparoscopic gastric bypass
Luiz Gonzaga De Moura-jÚnior1  Heládio Feitosa De Castro-filho1  Francisco Heine Ferreira Machado1  Rodrigo Feitosa Babadopulos1  Francisca Das Chagas FeijÓ1  Silvana Duarte Fernandes1 
关键词: Gastric bypass;    Human engineering;    Derivação gástrica;    Engenharia humana;    Obesidade;   
DOI  :  10.1590/S0102-6720201400S100019
来源: SciELO
PDF
【 摘 要 】

BACKGROUND: The laparoscopic access, with its classically known benefits, pushed implementation in other components, better ergonomy and aesthetic aspect. AIM: To minimize the number and diameter of traditional portals using miniport and flexible liver retractor on bariatric surgery. METHOD: This prospective study was used in patients with less than 45 kg/m2, with peripheral fat, normal umbilicus implantation, without previous abdominoplasties. Were used one 30o optical device with 5 mm in diameter, four accesses (one mini of 3 mm to the left hand of the surgeon, one of 5 mm to the right hand alternating with optics, one of 12 mm for umbilical for surgical maneuvers as dissection, clipping, in/out of gauze, and one portal of 5 mm for the assistant surgeon), resulting in a total of 25 mm linear incision; additionally, one flexible liver retractor (covered with a nelaton probe to protect the liver parenchyma, anchored in the right diaphragmatic pillar and going out through the surgeon left portal) to visualize the esophagogastric angle. RESULTS: In selected patients (48 operations), gastric bypass was performed at a similar time to the procedures with larger diameters (5 or 6 portals and 10 mm optics, with sum of linear incision of 42 mm) including oversuture line on excluded stomach, gastric tube and mesenteric closing. The non sutured portal of 3 mm and the two of 5 mm with subdermal sutures, were hardly visible in the folds of the skin; the one of 12 mm was buried inside the umbilicus or in the abdominoplasty incision. CONCLUSION: Minimizing portals is safe, effective, good ergonomic alternative with satisfactory aesthetic profile without need for specific instruments, new learning curve and limited movement of the instruments, as required by the single port.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130095357ZK.pdf 684KB PDF download
  文献评价指标  
  下载次数:35次 浏览次数:23次