期刊论文详细信息
Revista Brasileira de Ortopedia
Fracturing of revision of a cobalt-chrome femoral head after fracturing of a ceramic femoral head, with diffuse metallosis. Case report
Pedro Miguel Dantas Costa Marques1  Antonio Felix1  Bruno Alpoim1  Maria Elisa Rodrigues1  Pedro Sa1  Carolina Oliveira1  Francisco Lima Rodrigues1  Paulo Goncalves1  Maieiro Costa1  Antonio Rodrigues1 
关键词: Femur Head;    Ceramics Hip Prosthesis Metal Ceramic Alloys;    Cabeca do femur;    Ceramica;    protese de quadril;    Ligas metalo-ceramicas;   
DOI  :  10.1016/j.rboe.2012.05.008
来源: SciELO
PDF
【 摘 要 】

We presente a case of a fracture of a cobalt-chrome femoral head after revision of a hip total prosthesis with ceramic femoral head fracture. During surgery we found the cobalt-chrome femoral head fracture, wear of the polyethylene and massive metallosis in muscular and cartilaginous tissue. Both femoral stem and acetabular cup were stable and without apparent wearing. After surgical debridement, we promoted the substitution of the femoral head and the acetabular polyethylene by similar ones. After 12 months of follow-up, the patient has no pain complaints, function limit or systemic signs associated with malign metallosis

【 授权许可】

CC BY-NC-ND   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130094485ZK.pdf 1992KB PDF download