期刊论文详细信息
Química Nova
Determination of ochratoxin A in coriander (Coriandrum sativum L.) by HPCL/fluorescence detection
Celeste Matos Lino1  Lurdes Baeta1  Angelina Simões Pena1  Irene Noronha Silveira1 
关键词: ochratoxin A;    coriander;    HPLC;   
DOI  :  10.1590/S0100-40422006000300006
来源: SciELO
PDF
【 摘 要 】

An analytical study based on extraction with acetonitrile-water, immunoaffinity column cleanup, and HPLC/fluorescence detection for separation and identification of ochratoxin A in coriander was carried out. Validation of the applied methodology was done through accuracy and precision studies. Homogenized samples of coriander were spiked in triplicate with ochratoxin A at 0.5, 1.0, 2.0, and 5.0 µg/kg levels. Recovery values were in the range of 98% for a fortification level at 0.5 µg/kg to 109.1% at 1.0 µg/kg. Application to coriander samples available in Portuguese markes showed no contamination with ochratoxin A.

【 授权许可】

CC BY-NC   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130061789ZK.pdf 89KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:0次