期刊论文详细信息
Sensors
Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals
Isaac Ramos Pérez1  Xavi Bosch-Lluis1  Adriano Camps1  Nereida Rodriguez Alvarez1  Juan Fernando Marchán Hernandez1  Enric Valencia Domènech1  Carlos Vernich2  Sonia de la Rosa2 
[1] Remote Sensing Lab., Dept. Signal Theory and Communications, Universitat Politècnica de Catalunya (UPC) Campus Nord, Bldg D3, E-08034 Barcelona, Spain; E-Mails:;DAS Photonics, Ciudad Politécnica de la Innovación, Camino de Vera s/n, Edificio 8F, E-46022 Valencia, Spain; E-Mails:
关键词: correlation radiometers;    calibration;    Pseudo-Random Noise;    PRN;   
DOI  :  10.3390/s90806131
来源: mdpi
PDF
【 摘 要 】

The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers’ outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called “baseline errors” associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN) signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver’s output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.

【 授权许可】

CC BY   
© 2009 by the authors; licensee MDPI, Basel, Switzerland

【 预 览 】
附件列表
Files Size Format View
RO202003190056343ZK.pdf 670KB PDF download
  文献评价指标  
  下载次数:19次 浏览次数:1次