期刊论文详细信息
Sensors
Fabrication and Performance of All-Solid-State Chloride Sensors in Synthetic Concrete Pore Solutions
Xiaojian Gao1  Jian Zhang2  Yingzi Yang2 
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150006, China;
关键词: chloride sensor;    all-solid-state;    fabrication;    potentiometric response;    synthetic concrete pore solutions;   
DOI  :  10.3390/s10111022
来源: mdpi
PDF
【 摘 要 】

One type of all-solid-state chloride sensor was fabricated using a MnO2 electrode and a Ag/AgCl electrode. The potentiometric response of the sensor to chloride in synthetic concrete pore solutions was systematically studied, and the polarization performance was also evaluated. The results show a good linear relationship between the potential reading of the sensor and the logarithm of chloride activity (concentration ranges from 0.05 to 5.0 M), and the potential value remains stable with increasing immersion time. The existence of K+, Ca2+, Na+ and SO42− ions have little influence on the potentiometric response of the sensor to chloride, but the pH has a significant influence on the potential value of the sensor at low chloride concentration. The potential reading of the sensor increases linearly with the solution temperature over the range from 5 to 45 °C. Meanwhile, an excellent polarization behavior is proven by galvanostatic and potentiodynamic tests. All of the results reveal that the developed sensor has a great potential for monitoring chloride ions in concrete environments.

【 授权许可】

CC BY   
© 2010 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190051733ZK.pdf 207KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:19次