Susceptibility of Mycobacterium immunogenum and Pseudomonas fluorescens to Formaldehyde and Non-Formaldehyde Biocides in Semi-Synthetic Metalworking Fluids
Mycobacterium immunogenum, a newly identified member of the Mycobacterium chelonae_M. abscessus complex is considered a potential etiological agent for hypersensitivity pneumonitis (HP) in machine workers exposed to contaminated metalworking fluid (MWF). This study investigated the biocidal efficacy of the frequently applied commercial formaldehyde-releasing (HCHO) biocides Grotan and Bioban CS 1135 and non-HCHO type biocides Kathon 886 MW (isothiazolone) and Preventol CMK 40 (phenolic) toward this emerging mycobacterial species (M. immunogenum) in HP-linked MWFs, alone and in presence of a representative of the Gram-negative bacterial contaminants, Pseudomonas fluorescens, using two semi-synthetic MWF matrices (designated Fluid A and Fluid B). Relative biocide susceptibility analysis indicated M immunogenum to be comparatively more resistant (2–1600 fold) than P. fluorescens to the tested biocides under the varied test conditions. In terms of minimum inhibitory concentration, Kathon was the most effective biocide against M. immunogenum. Fluid factors had a major effect on the biocide susceptibility. Fluid A formulation provided greater protective advantage to the test organisms than Fluid B. Fluid dialysis (Fluid A) led to an increased biocidal efficacy of Grotan, Kathon and Preventol against M. immunogenum further implying the role of native fluid components. Used fluid matrix, in general, increased the resistance of the two test organisms against the biocides, with certain exceptions. M. immunogenum resistance increased in presence of the co-contaminant P. fluorescens. Collectively, the results show a multifactorial nature of the biocide susceptibility of MWF-colonizing mycobacteria and highlight the importance of more rigorous efficacy testing and validation of biocides prior to and during their application in metalworking fluid operations.