期刊论文详细信息
Sensors
Inertial Sensing to Determine Movement Disorder Motion Present before and after Treatment
Wesley J. E. Teskey1  Mohamed Elhabiby1 
[1] Department of Geomatics Engineering, 2500 University Drive NW, University of Calgary, Calgary, Alberta T2N 1N4, Canada; E-Mails:
关键词: accelerometer;    gyroscope;    Parkinson’s disease;    essential tremor;   
DOI  :  10.3390/s120303512
来源: mdpi
PDF
【 摘 要 】

There has been a lot of interest in recent years in using inertial sensors (accelerometers and gyroscopes) to monitor movement disorder motion and monitor the efficacy of treatment options. Two of the most prominent movement disorders, which are under evaluation in this research paper, are essential tremor (ET) and Parkinson’s disease (PD). These movement disorders are first evaluated to show that ET and PD motion often depict more (tremor) motion content in the 3–12 Hz frequency band of interest than control data and that such tremor motion can be characterized using inertial sensors. As well, coherence analysis is used to compare between pairs of many of the six degrees-of-freedom of motions under evaluation, to determine the similarity in tremor motion for the various degrees-of-freedom at different frequency bands of interest. It was quite surprising that this coherence analysis depicts that there is a statistically significant relationship using coherence analysis when differentiating between control and effectively medicated PD motion. The statistical analysis uncovers the novel finding that PD medication induced dyskinesia is depicted within coherence data from inertial signals. Dyskinesia is involuntary motion or the absence of intended motion, and it is a common side effect among medicated PD patients. The results show that inertial sensors can be used to differentiate between effectively medicated PD motion and control motion; such a differentiation can often be difficult to perform with the human eye because effectively medicated PD patients tend to not produce much tremor. As well, the finding that PD motion, when well medicated, does still differ significantly from control motion allows for researchers to quantify potential deficiencies in the use of medication. By using inertial sensors to spot such deficiencies, as outlined in this research paper, it is hoped that medications with even a larger degree of efficacy can be created in the future.

【 授权许可】

CC BY   
© 2012 by the authors; licensee MDPI, Basel, Switzerland

【 预 览 】
附件列表
Files Size Format View
RO202003190045365ZK.pdf 721KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:3次