| Sensors | |
| An Exfoliated Graphite-Based Bisphenol A Electrochemical Sensor | |
| Thabile Ndlovu1  Omotayo A. Arotiba1  Srinivasan Sampath1  Rui W. Krause1  | |
| [1] Department of Applied Chemistry, University of Johannesburg, P.O. Box 17011, Doornfontein 2028, Johannesburg, South Africa; E-Mails: | |
| 关键词: exfoliated graphite electrode; bisphenol A; phenol; electrode fouling; pollutant; | |
| DOI : 10.3390/s120911601 | |
| 来源: mdpi | |
PDF
|
|
【 摘 要 】
The use of an exfoliated graphite (EG) electrode in the square wave voltammetric detection of bisphenol A (a model phenolic pollutant) in water, whereby the phenolic electrode fouling challenge is mitigated, is described. The oxidation peak of BPA was observed at about 0.45 V in phosphate buffer solution at pH 10. The current response exhibited a linear relationship with the concentration over a range from 1.56 μM–50 μM. The detection limit was calculated to be 0.76 μM. The EG electrode surface was renewed after each measurement with excellent reproducibility. A real sample application was also investigated.
【 授权许可】
CC BY
© 2012 by the authors; licensee MDPI, Basel, Switzerland.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202003190042098ZK.pdf | 605KB |
PDF