期刊论文详细信息
Sensors
An Exfoliated Graphite-Based Bisphenol A Electrochemical Sensor
Thabile Ndlovu1  Omotayo A. Arotiba1  Srinivasan Sampath1  Rui W. Krause1 
[1] Department of Applied Chemistry, University of Johannesburg, P.O. Box 17011, Doornfontein 2028, Johannesburg, South Africa; E-Mails:
关键词: exfoliated graphite electrode;    bisphenol A;    phenol;    electrode fouling;    pollutant;   
DOI  :  10.3390/s120911601
来源: mdpi
PDF
【 摘 要 】

The use of an exfoliated graphite (EG) electrode in the square wave voltammetric detection of bisphenol A (a model phenolic pollutant) in water, whereby the phenolic electrode fouling challenge is mitigated, is described. The oxidation peak of BPA was observed at about 0.45 V in phosphate buffer solution at pH 10. The current response exhibited a linear relationship with the concentration over a range from 1.56 μM–50 μM. The detection limit was calculated to be 0.76 μM. The EG electrode surface was renewed after each measurement with excellent reproducibility. A real sample application was also investigated.

【 授权许可】

CC BY   
© 2012 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190042098ZK.pdf 605KB PDF download
  文献评价指标  