Multi-Sensor Approach for the Monitoring of Halitosis Treatment via Lactobacillus brevis (CD2)—Containing Lozenges—A Randomized, Double-Blind Placebo-Controlled Clinical Trial
Enrico Marchetti2  Simona Tecco3  Marco Santonico1  Chiara Vernile1  Daniele Ciciarelli2  Ester Tarantino2  Giuseppe Marzo2  Giorgio Pennazza1 
[1] Center for Integrated Research—CIR, Unit of Electronics for Sensor Systems, “Università Campus Bio-Medico di Roma”, Via Alvaro del Portillo 21, 00128 Rome, Italy; E-Mails:;Department MESVA, University of L’Aquila, Via Vetoio ed. Delta 6, 67100 L’Aquila, Italy; E-Mails:;University Vita-Salute San Raffaele, I.R.R.C.S. San Raffaele Hospital, 20100 Milano, Italy; E-Mail:
关键词: halitosis;    bad breath;    electronic nose;    chemical sensors;    sensor array;    probiotics;   
DOI  :  10.3390/s150819583
来源: mdpi
PDF
【 摘 要 】

The aim of this randomized clinical trial was to evaluate whether a recently described multi-sensor approach called BIONOTE® is accurate enough to verify the efficacy of treatment of patients with halitosis. A treatment with Lactobacillus brevis (CD2)–containing lozenges, compared with placebo was tested. The BIONOTE® was compared with traditional techniques used to detect halitosis: OralChroma™ and two calibrated odor judges enrolled for the organoleptic assessments. Twenty patients (10 treated and 10 placebo), suffering from active phase halitosis were included in the study. Treatment consisted of Lactobacillus brevis (CD2)—containing lozenges or placebo, 4 tablets/day for 14 days. t0 was before the beginning of the study; t1 was day 7 and t2 was day 14. The effectiveness of treatment was assessed through: (1) Rosenberg score; (2) Winkel tongue coating index (WTCI) anterior and posterior; (2) OralChroma™; (3) the new developed multi-sensor approach, called BIONOTE® (test technique). Only the WTCI anterior revealed statistically significant changes between t0 and t2 data (p = 0.014) in the treated group. Except for the WTCI anterior, all diagnostic methods revealed the lack of effectiveness for halitosis of a 14-days treatment with Lactobacillus brevis (CD2)–containing lozenges. The BIONOTE® multisensor system seems accurate in addition to OralChroma™ to assess the initial condition of halitosis and its mitigation during treatment.

【 授权许可】

CC BY   
© 2015 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190008294ZK.pdf 1141KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:22次