期刊论文详细信息
Polymers
Seismic Behavior of Substandard RC Columns Retrofitted with Embedded Aramid Fiber Reinforced Polymer (AFRP) Reinforcement
Engin C. Seyhan2  Caglar Goksu1  Ahmet Uzunhasanoglu2  Alper Ilki2 
[1] Department of Civil Engineering, Civil Engineering Faculty, Istanbul Technical University, Ayazaga, Sariyer, Istanbul 34469, Turkey
关键词: aramid;    flexure;    FRP reinforcement;    reinforced concrete;    retrofitting;    seismic;   
DOI  :  10.3390/polym7121527
来源: mdpi
PDF
【 摘 要 】

Many existing reinforced concrete structures were constructed with substandard characteristics. Low quality concrete, poor transverse reinforcement details and insufficient flexural strength are among the most common deficiencies. While substandard structures are in need of retrofitting, particularly in seismic areas, problems such as high costs and disturbance to occupants are major obstacles for retrofit interventions. Fiber reinforced polymers can provide feasible retrofit solutions with minimum disturbance to occupants. In this study, the basic aim is to investigate the flexural seismic performance of substandard reinforced concrete columns retrofitted with embedded longitudinal fiber reinforced polymer reinforcement without increasing the original dimensions of the columns. In the experimental study, the reference and retrofitted columns were tested under constant vertical and reversed cyclic lateral loads. Three different connection methods of aramid fiber reinforced polymer reinforcement to the footing were investigated experimentally. A significant enhancement was obtained in lateral flexural strength through the proposed retrofitting method. Furthermore, it was observed that the cyclic lateral drift capacities of the retrofitted columns were as high as 3%, which can be deemed as quite satisfactory against seismic actions. The comparison of the experimental data with analytical calculations revealed that a conventional design approach assuming composite action between concrete and fiber reinforced polymer reinforcement can be used for flexural retrofit design. Experimental results also demonstrated that strain limit for longitudinal fiber reinforced polymer (FRP) reinforcement should be remarkably lower in case of reversed cyclic loading conditions.

【 授权许可】

CC BY   
© 2015 by the authors; licensee MDPI, Basel, Switzerland.

【 预 览 】
附件列表
Files Size Format View
RO202003190002405ZK.pdf 6526KB PDF download
  文献评价指标  
  下载次数:24次 浏览次数:42次