Influence of Operating Pressure on Gas Holdup and Flow Regime Transition in a Bubble Column
Hiroaki Matsubara1  Toshiyuki Sakaguchi1  Kiyoshi Naito1  Hideharu Kuwamoto1 
[1]Process Technology Center, Mitsui Chemicals, Inc.
关键词: Bubble Columns;    High Pressure;    Gas Holdup;    Flow Regime;    Organic Solvents;   
DOI  :  10.1252/jcej.10we157
来源: Maruzen Company Ltd
PDF
【 摘 要 】
References(8)Cited-By(2)The effect of elevated pressures on the gas holdup and flow regime transition in a gas–liquid bubble column is examined. Experiments are carried out in a bubble column of 0.3 m diameter at system pressures between 0.1 and 0.6 MPa, using different liquids sparged with nitrogen. The following results are obtained. (1) The superficial gas velocity at the flow regime transition point (Utrans) increases with the system pressure. (2) In the bubbly flow regime, the gas holdup shows no notable change when the superficial gas velocity is maintained at a low value. However, in the churn-turbulent flow regime, the gas holdup increases with the system pressure. These phenomena are in agreement with those predicted on the basis of the equations for Utrans and gas holdup, proposed previously.