Gas Holdup in a Bench-Scale Direct Coal Liquefaction Reactor
Shigeru Ueda2  Hideo Narita1  Tadashi Yoshida1  Kiyoshi Idogawa1  Shinichi Yokoyama1  Masahide Sasaki1  Takashi Fukuda1  Tadatoshi Chiba3  Takeshi Kotanigawa1  Toshimasa Hirama1  Mituyoshi Yamamoto1  Hiroshi Nagaishi1  Akiyoshi Sasaki1  Ryoichi Yoshida1  Yosuke Maekawa1 
[1] Hokkaido National Industrial Research Institute;New Energy and Ind. Tech. Dev. Organization;Dept. of Metallurgical Eng., Hokkaido Univ.
关键词: Gas Holdup;    Coal Liquefaction;    High Pressure;    High Temperature;    Slurry Reactor;    Gas Density;    Liquid Density;   
DOI  :  10.1252/jcej.27.95
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(20)Gas holdup was measured for gas-liquid (hydrogen gas/decrystallized anthracene oil/creosote oil) system and gas-slurry (hydrogen gas/Taiheiyo coal particles/decrystallized anthracene oil) systems in a 0.1 ton/day continuous direct coal liquefaction reactor. The measurements were carried out at temperatures ranging from 289 K to 723 K and a pressure of 30 MPa by two methods, a differential pressure method for the gas-liquid systems and a gas-quenching method for the gas-slurry system.The gas holdups for both systems were correlated with the gas flow pattern just above the reactor entrance. Though the present gas holdup data were in reasonable agreement with those published by other investigators, a difference was found between the dependencies of gas holdup on superficial gas velocity in the preheater and in the reactor.