期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Characteristics of a Flow-Channel Type Sonochemical Reactor Equipped with Multitransducer
Tatsuro Matsuoka2  Tomoyuki Nishida2  Shinobu Koda2  Yoshiyuki Asakura2  Susumu Nii1 
[1] Department of Chemical Engineering, Graduate School of Engineering, Nagoya University;Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University
关键词: Ultrasound;    Potassium Iodide;    Oxidation;    Sonochemical Reactor;    Continuous Operation;   
DOI  :  10.1252/jcej.40.497
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(11)Cited-By(4)Ultrasound was irradiated to an aqueous solution of KI for oxidizing iodide ions in a rectangular-channel type sonoreactor with 14 oscillators mounted in series. The ultrasonic frequency was 133.2 kHz. For different setting conditions with or without a reflector, the reaction was carried out in a batch and continuous operation mode, and the conversion of iodide ions was compared to investigate the characteristics of a reactor. Under the batch operation mode, a reaction rate constant without a reflector was higher than that with a reflector. For a continuous mode, similar rate constants were observed for both conditions with and without a reflector, and the constants were close to that for the batch mode with a reflector. The results indicate that horizontal sweeping flow along the air-liquid interface may have suppressed the cavitation. The effect of the liquid flow should be taken into consideration to design flow-type sonochemical reactors.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080696084ZK.pdf 19KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:25次