期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Improvement in Failure Diagnosis of Flowmeters Based on Control Limits
Yoshifumi Tsuge1  Hisayoshi Matsuyama1  Kazuhiro Takeda1  Kazushi Ishimoto1 
[1] Department of Chemical Engineering, Faculty of Engineering, Kyushu University
关键词: Failure Detection;    Failure Diagnosis;    Flowmeter;    Control Limit;    Linear Programming;   
DOI  :  10.1252/jcej.37.1243
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(10)Failure diagnosis of flowmeters based on control limits has been developed as a method to identify faulty flowmeters, which should be calibrated during a maintenance period, during plant operation. This method is very useful for the diagnosis of flowmeters having faulty errors with magnitudes greater than three times of their control limits. However, there is a shortcoming that the diagnostic results given by this method often miss giving alarms when they should, or give false diagnoses, for faulty errors with magnitudes less than three times of their control limits. In this study, the diagnostic results given by this method during plant operation are not adopted in a straightforward manner. Instead, at least one flowmeter is selected and calibrated during a maintenance period, to identify the true value of a flow rate. As a result, the diagnostic accuracy can be improved by performing a second diagnosis using the calibrated values of the flow rates. Furthermore, the performance of the method presented is demonstrated by numerical experiments on a simplified refinery model containing 11 flowmeters.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080695431ZK.pdf 19KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:33次