期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Bubble Size Measurement in a Gas-Liquid Ejector for a Sodium Chloride-Air System
P. T. Raghuram1  T. R. Das1 
[1] Department of Chemical Engineering, Indian Institute of Science
关键词: Bubble Size Measurement;    Ejector;    Photographic Method;    Sauter Mean Diameter;    Non-reactive System;   
DOI  :  10.1252/jcej.35.389
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(11)A high speed photographic technique has been employed to measure the Sauter mean diameter of bubbles experimentally in a gas liquid ejector using a sodium chloride-air system. The measured values are compared with the theoretically predicted maximum bubble size diameter using Sprow’s correlation. Bubble size as a function of the liquid flow rate and also of its distance from the throat of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those obtained earlier for the air-water system.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080695104ZK.pdf 19KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:22次