期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Dew Points of Ternary Propane + Water + Methanol: Measurement and Correlation
INMACULADA VELASCO1  SOFÍA BLANCO1  SANTOS OTÍN1  EVELYNE RAUZY2 
[1] Departamento de Química Orgánica y Química Física, Facultad de Ciencias, Universidad de Zaragoza;Laboratoire de Chimie Physique de Marseille, Faculté des Sciences de Luminy, Université de la Mediterranée
关键词: Dew Point;    Experimental Method;    Equation of State;    Excess Function;   
DOI  :  10.1252/jcej.34.971
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(33)Cited-By(2)Experimental measurements of dew points for ternary propane + water + methanol were carried out between 0.99 × 105 Pa and 5.43 × 105 Pa and the temperature range from 254.2 K to 282.7 K. An EOS-CR method (equation of state-chemical reticular) reproduces the experimental dew temperature data within average absolute deviation (AAD) from 0.8 to 3.2 K.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080694966ZK.pdf 19KB PDF download