期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Correlation of Solid Holdup in Liouid-Solid Fluidized Bed
Nobuyuki Hidaka2  Toshitatsu Matsumoto2  Kazuhiro Kakoi2  Shigeharu Morooka1 
[1] Department of Chemical Science and Technology, Kyushu University;Department of Applied Chemistry and Chemical Engineering, Kagoshima University
关键词: Fluidization;    Liquid Fluidized Bed;    Slip Velocity;    Solid Holdup;    Void Function;   
DOI  :  10.1252/jcej.27.563
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(21)Cited-By(7)Solid holdup in vertical fluidized beds for liquid-solid systems was investigated over a wide range of experimental conditions. The solid phases used were sieved glass beads of diameters 66, 118, 243, 465, 900, 2200, 3100 and 4650 μm, sieved porous alumina particles of diameter 3680 μm and sieved ion exchange resin particles of diameter 610 μm. The liquid phase was tap water. The effect of column diameter on solid holdup was negligible when the column diameter was larger than 0.0397 m. A novel model for predicting solid holdup in all flow regimes was developed. Experimental data, including previous results in the literature, were in good agreement with the model.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080693783ZK.pdf 801KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:12次