期刊论文详细信息
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Correlation of Mass Transfer Volumetric Coefficient with Power Input in Stirred Liquid-Liquid Dispersions
Ikuho Yamada1  Tsutomu Aragaki1  Hiyori Suzuki1  Yutaka Tada1  Hideki Mori1  Setsuro Hiraoka1 
[1] Nagoya Institute of Technology
关键词: Mass Transfer;    Agitated Vessel;    Liquid Liquid System;    Mass Transfer Coefficient;    Volumetric Coefficient;    Droplet Diameter;    Hydrolysis Reaction;   
DOI  :  10.1252/jcej.23.468
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(14)Cited-By(17)A continuous-phase mass transfer volumetric coefficient kLa in stirred liquid-liquid dispersions was measured under many stirring conditions by using the hydrolysis reaction of ester with sodium hydroxide. Droplet diameter was also observed with a microscope during the period of reaction progress, allowing the continuous-phase mass transfer coefficient kL to be determined. The resultant kL was correlated with the power input per unit volume and the Sauter mean diameter d32. With the help of the kL correlation equation, d32 was well correlated with the power input per unit volume swept out by the impeller. The kLa values estimated from both the kL correlation equation and the d32 correlation equation agreed well with the observed values.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912080693183ZK.pdf 1365KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:16次