JOURNAL OF CHEMICAL ENGINEERING OF JAPAN | |
Measurement of Continuous-Phase Mass Transfer Coefficient at Droplet Surface in Liquid-Liquid Mixing Vessel by Chemical Reaction Method | |
Ikuho Yamada2  Tsutomu Aragaki2  Hiyori Suzuki2  Young Tae Park1  Yutaka Tada2  Hideki Mori2  Setsuro Hiraoka2  Naoki Narita2  | |
[1] Kyungpook Open University;Nagoya Institute of Technology | |
关键词: Mass Transfer Coefficient; Droplet Diameter; Hydrolysis Reaction; Mixing Vessel; Ester; Liquid Liquid System; | |
DOI : 10.1252/jcej.23.166 | |
来源: Maruzen Company Ltd | |
【 摘 要 】
References(19)Cited-By(5)The continuous-phase mass transfer volumetric coefficient kLa in a liquid-liquid mixing vessel was measured by using the hydrolysis reaction of both n-amyl and n-hexyl acetates with sodium hydroxide. Droplet diameter was also observed by using a videorecorder via a microscope during the reaction period, allowing the continuous-phase mass transfer coefficient, kL, to be determined. The coefficient obtained was 2–5 times larger than that obtained from the correlation by Calderbank–MooYoung. Dimensionless correlation of the mass transfer coefficient with the droplet diameter and the power input per unit volume was confirmed experimentally to be close to that for the solid suspension system.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912080693128ZK.pdf | 770KB | download |