期刊论文详细信息
Fizika B (Zagreb)
RADIATION HARDNESS OF THE PIBETA DETECTOR COMPONENTS
E. FRLE1  I. J. CAREY andD. POANI1  T. A. CAMPBELL1 
关键词: long-term temporal stability of detector gain;    energy resolution anddetection efficiency;    radiation hardness;    radiation resistance;    radiation damage;   
DOI  :  
学科分类:物理(综合)
来源: Fizika B: a journal of experimental and theoretical physics
PDF
【 摘 要 】

We have examined long-term changes in signal amplitude gain, energy resolution anddetection efficiency of the active components of the PIBETA detector system. Beam-definingplastic scintillation counters were operated in a ~1MHz stoppedp+ beam for a period of 297 days, accumulatingradiation doses of up to 2106 rad. Detectors in the charged particletracking system - a pair of cylindrical multi-wire proportional chambers and a thinplastic scintillation barrel-shaped hodoscope array - were irradiated during the samerunning period with an average dose of ~ 4 104 rad.Individual CsI (undoped crystal) calorimeter detectors received an average dose of ~  120 rad, mainly from photons, positrons and protonsoriginating from p+ hadronic interactions as well asfrom p+ and m+weak decays at rest in the active target.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912050588911ZK.pdf 1238KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:8次