Fizika B (Zagreb) | |
RADIATION HARDNESS OF THE PIBETA DETECTOR COMPONENTS | |
E. FRLE1  I. J. CAREY andD. POANI1  T. A. CAMPBELL1  | |
关键词: long-term temporal stability of detector gain; energy resolution anddetection efficiency; radiation hardness; radiation resistance; radiation damage; | |
DOI : | |
学科分类:物理(综合) | |
来源: Fizika B: a journal of experimental and theoretical physics | |
【 摘 要 】
We have examined long-term changes in signal amplitude gain, energy resolution anddetection efficiency of the active components of the PIBETA detector system. Beam-definingplastic scintillation counters were operated in a ~1MHz stoppedp+ beam for a period of 297 days, accumulatingradiation doses of up to 2106 rad. Detectors in the charged particletracking system - a pair of cylindrical multi-wire proportional chambers and a thinplastic scintillation barrel-shaped hodoscope array - were irradiated during the samerunning period with an average dose of ~ 4 104 rad.Individual CsI (undoped crystal) calorimeter detectors received an average dose of ~ 120 rad, mainly from photons, positrons and protonsoriginating from p+ hadronic interactions as well asfrom p+ and m+weak decays at rest in the active target.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912050588911ZK.pdf | 1238KB | download |