Journal of the Brazilian Chemical Society | |
Cathodic voltammetric detection of diltiazem at a bismuth film electrode: application to human urine and pharmaceuticals | |
Pimenta, Adriana M.1  Souto, M. Renata S.1  Lopes, Joana R. T.1  Catarino, Rita I. L.1  Leal, M. Fernanda C.1  University Fernando Pessoa, Porto, Portugal1  | |
关键词: bismuth film electrode; diltiazem; voltammetry; pharmaceuticals; | |
DOI : 10.5935/0103-5053.20140067 | |
学科分类:化学(综合) | |
来源: SciELO | |
【 摘 要 】
In this work it was developed a novel application of bismuth film electrodes (BiFEs) for the determination of the antihypertensive and coronary vasodilator diltiazem by square wave cathodic voltammetry. The bismuth film was deposited ex situ on a glassy carbon electrode for 90 s at 1.4 V vs. Ag/AgCl, from an acetate buffer (pH 4.5; 0.10 mol L-1) containing 5 or 30 mg L-1 Bi. Diltiazem analytical signal was obtained in phosphate buffer (pH 7.4; 0.25 mol L-1) where reduction takes place at 1.5 V vs. Ag/AgCl. The proposed methodology was applied to the quantification of diltiazem in pharmaceutical samples (dynamic linear range comprised between 90 and 900 µg L-1) and in human urine (dynamic linear range comprised between 45 and 270 µg L-1, and detection limit of 12 µg L-1).
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912050582193ZK.pdf | 281KB | download |