| Journal of the Brazilian Chemical Society | |
| Simultaneous voltammetric determination of acetaminophen and caffeine at a graphite and polyurethane screen-printed composite electrode | |
| Cavalheiro, Éder T. G.1  Saciloto, Thalita R.1  Universidade de São Paulo, São Carlos, Brazil1  Cervini, Priscila1  | |
| 关键词: acetaminophen; screen printed electrode; graphite-polyurethane composite; | |
| DOI : 10.5935/0103-5053.20130186 | |
| 学科分类:化学(综合) | |
| 来源: SciELO | |
PDF
|
|
【 摘 要 】
A selective electrochemical method was developed for the individual or simultaneous determination of acetaminophen and caffeine in phosphate buffer pH 6.0 on graphite and polyurethane screen-printed composite electrode (EIGPU) using Differential Pulse Voltammetry (DPV). The oxidation peaks of acetaminophen and the caffeine appeared at 0.3 V and 1.3 V(vs. pseudo-Ag/AgCl), respectively, showing the possibility of simultaneous determination of both analytes, at the EIGPU, besides the individual determination. Analytical curves for the simultaneous determination showed a linear response for both compounds. The acetaminophen presented a linear region in the concentration range 1.00 - 40.0 µmol L-1 with detection limit of 0.84 µmol L-1, and the caffeine presented a linear region, in the concentration range 4.00 - 200 µmol L-1 with detection limit of 1.6 µmol L-1. The proposed method was applied in the simultaneous determination of acetaminophen and caffeine in three pharmaceutical formulations, with results similar to those obtained using a HPLC method, at 95% confidence level (Student t-Test).
【 授权许可】
Unknown
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201912050581988ZK.pdf | 757KB |
PDF