期刊论文详细信息
Pramana
Imperative function of electron beams in low-energy plasma focus device
M Z Khan1 21  L K Lim1  S L Yap1  C S Wong1 
[1] Plasma Technology Research Centre, Department of Physics, Faculty of Science, University Malaya, 50603 Kuala Lumpur, Malaysia$$
关键词: Dense plasma focus;    X-ray yield;    electron beam energy;    photomultiplier tube;    X-ray spectrometer.;   
DOI  :  
学科分类:物理(综合)
来源: Indian Academy of Sciences
PDF
【 摘 要 】

A 2.2 kJ plasma focus device was analysed as an electron beam and an X-ray source that operates with argon gas refilled at a specific pressure. Time-resolved X-ray signals were observed using an array of PIN diode detectors, and the electron beam energy was detected using a scintillator-assisted photomultiplier tube. The resultant X-rays were investigated by plasma focus discharge for pressures ranging from 1.5 mbar to 2.0 mbar. This range corresponded to the significant values of X-ray yields and electron beam energies from the argon plasma. The electron temperature of argon plasma at an optimum pressure range was achieved by an indirect method using five-channel BPX65 PIN diodes of aluminum foils with different thicknesses. X-ray yield, electron beam energy, and electron temperature of argon plasma were achieved at 1.5–2.0 mbar because of the strong bombardment of the energetic electron beam.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912040499238ZK.pdf 550KB PDF download