FEBS Letters | |
Dual effects of microwaves on single Ca2+‐activated K+ channels in cultured kidney cells Vero | |
Chemeris, Nicolay K.2  Geletyuk, Vitaliy I.2  Fesenko, Evgeniy E.1  Kazachenko, Vladimir N.2  | |
[1] Laboratory of Reception Biophysics, Institute of Cell Biophysics of Russian Academy of Sciences, Pushchino, Moscow Region, 142292, Russian Federation;Laboratory of Nerve Cell Biophysics, Institute of Cell Biophysics of Russian Academy of Sciences, Pushchino, Moscow Region, 142292, Russian Federation | |
关键词: Ca2+-activated K+ channel; Excised membrane patch; Millimetre microwave; Kidney cell Vero; | |
DOI : 10.1016/0014-5793(95)00002-Q | |
学科分类:生物化学/生物物理 | |
来源: John Wiley & Sons Ltd. | |
【 摘 要 】
Using the patch voltage-clamp method, possible effects of millimetre microwaves (42.25 GHz) on single Ca2+-activated K+ channels in cultured kidney cells (Vero) were investigated. It was found that exposure to the field of non-thermal power (about 100 μW/cm2) for 20–30 min greatly modifies both the Hill coefficient and an apparent affinity of the channels for Cai 2+. The data suggest that the field alters both cooperativity and binding characteristics of the channel activation by internal Ca2+. The effects depend on initial sensitivity of the channels to Ca2+ and the Ca2+ concentration applied.
【 授权许可】
Unknown
【 预 览 】