New PVC based polymeric membrane electrodes (PME) and coated glassy carbon electrodes (CGCE) based on synthesized Schiff base complexes of Co(III); [Co(Salen)(PBu3)2]ClO4, [Co(Me2Salen)(PBu3)2]ClO4, [Co(Salen)(PBu3)H2O]ClO4; as anion carriers for potentiometric determination of ClO4 ? were studied. The PME and also CGCE electrodes prepared with [Co(Me2Salen)(PBu3)2]ClO4 showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to ClO4 ? ions over a wide concentration range with low detection limits (1.0 �? 10-6 mol L-1 for PME and 9.0 �? 10-7 mol L-1 for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward ClO4 ? relative to a variety of other common inorganic anions. The potentiometric response of the electrodes is independent of the pH in the pH range 2.5-8.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water and urine samples. The interaction of the ionophore with perchlorate ions was shown by UV/Vis spectroscopy.