期刊论文详细信息
Journal of Nuclear Medicine
Repeatability of Metabolically Active Volume Measurements with 18F-FDG and 18F-FLT PET in Non–Small Cell Lung Cancer
Egbert F. Smit1  Floris H.P. van Velden1  Virginie Frings1  Harm van Tinteren1  Otto S. Hoekstra1  Adrianus J. de Langen1  Ronald Boellaard1 
关键词: positron emission tomography;    non–small-cell lung cancer;    repeatability;    metabolic volume;    18F-FLT;    18F-FDG;   
DOI  :  10.2967/jnumed.110.077255
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

In addition to tumor size measurements with CT, there is a need for quantitative measurements of metabolic active volumes, possibly adding to tracer uptake measurements in oncologic response evaluation with PET. The aim of this study was to evaluate the metabolic volume test–retest variability in 18F-FDG and 3′-deoxy-3′-18F-fluorothymidine (18F-FLT) PET studies for various commonly used volumes of interest (VOIs) and the dependence of that variability on lesion size and relative radiotracer uptake. Methods: Twenty non–small cell lung cancer patients were scanned twice with 18F-FDG (n = 11) or 18F-FLT (n = 9). VOIs were defined on images reconstructed with normalization- and attenuation-weighted ordered-subset expectation maximization using 4 isocontours (A41%, A50%, and A70% thresholds, adapted for local background, and 50% threshold, uncorrected for background). Statistical analysis comprised intraclass correlation coefficients and Bland–Altman analysis. Results: In the 18F-FDG and 18F-FLT groups, 34 and 20 lesions, respectively, were analyzed. Median volumes at the A50% threshold were 3.31 and 2.19 mL (interquartile range, 1.91–8.90 and 1.52–7.27 mL) for 18F-FDG and 18F-FLT, respectively. Intraclass correlation coefficients were greater than 0.9, with the exception of the A70%-based metabolic volumes for 18F-FLT. For lesions greater than 4.2 mL, repeatability coefficients (RCs = 1.96 × SD) of the percentage difference ranged from 22% to 37% for 18F-FDG and from 39% to 73% for 18F-FLT, depending on the VOI method being used. Repeatability was better for larger tumors, but there was no dependence on absolute uptake (standardized uptake value). Conclusion: Results indicate that changes of greater than 37% for 18F-FDG and greater than 73% for 18F-FLT (1.96 × SD) for lesions with A50% metabolic volumes greater than 4.2 mL represent a biologic effect. For smaller lesions (A50% VOI < 4.2 mL), an absolute change of 1.0 and 0.9 mL for 18F-FDG and 18F-FLT, respectively, is biologically relevant. Considering the balance between the success rate of automatic tumor delineation and repeatability of metabolic volume, a 50% threshold with correction for local background activity (A50%) seems optimal among the VOI methods evaluated.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010197633ZK.pdf 739KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:6次