期刊论文详细信息
Journal of Nuclear Medicine
Tissue Characterization of Solitary Pulmonary Nodule: Comparative Study Between Helical Dynamic CT and Integrated PET/CT
Byung-Tae Kim1  Joon Young Choi1  Chin A Yi1  Myung Jin Chung1  O. Jung Kwon1  Kyung Soo Lee1  Young Mog Shim1  Hojoong Kim1 
关键词: lung neoplasms;    diagnosis;    lung neoplasms;    CT;    lung neoplasms;    PET;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Recent advances in the technology of helical multidetector CT allow precise evaluations of nodule hemodynamics. In addition, the efficacy of tissue characterization has improved, and now sensitivity and specificity of >90% are achieved. Moreover, the efficacy of PET for the tissue characterization of solitary pulmonary nodules (SPNs) has also become of importance. The purpose of this study was to compare the diagnostic accuracy of helical dynamic (HD) CT (HDCT) and integrated PET/CT for pulmonary nodule characterization. Methods: One hundred nineteen patients with an SPN underwent both HDCT (unenhanced scans, followed by series of images at 30, 60, 90, 120 s and at 5 and 15 min after intravenous injection of contrast medium) and integrated PET/CT. On HDCT, a nodule was regarded as malignant with a net enhancement of ≥25 Hounsfield units (HU) and a washout of 5–31 HU. On integrated PET/CT, nodules were considered malignant with a ≥3.5 maximum standardized uptake value and an 18F-FDG uptake greater than that of mediastinal structures. The sensitivity, specificity, and accuracy of the 2 modalities for malignancy were compared using the McNemar test. Results: There were 79 malignant and 40 benign nodules. The sensitivity, specificity, and accuracy for malignancy on HDCT were 81% (64/79 nodules), 93% (37/40), and 85% (101/119), respectively, whereas those on integrated PET/CT were 96% (76/79), 88% (35/40), and 93% (111/119), respectively (P = 0.008, 0.727, and 0.011, respectively). All malignant nodules were interpreted correctly on either HDCT or PET/CT. Conclusion: Integrated PET/CT is more sensitive and accurate than HDCT for the malignant nodule characterization; therefore, PET/CT may be performed as the first-line evaluation tool for SPN characterization. Because HDCT has high specificity and acceptable sensitivity and accuracy, it may be a reasonable alternative for nodule characterization when PET/CT is unavailable.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010196554ZK.pdf 632KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:3次