期刊论文详细信息
Journal of Nuclear Medicine
Preliminary Evaluation of a Fuzzy Logic-Based Automatic Quantitative Analysis in Myocardial SPECT
Aimé Amonchot1  Florent Cachin1  Jean Ponsonnaille1  Danièle Mestas1  Janusz Lipiecki1  Benjamin Geissler1  Jean Maublant1  Cyril Thouly1 
关键词: myocardial perfusion imaging;    quantification;    reproducibility;    coronary artery disease;   
DOI  :  
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

This study validates a new quantitative myocardial perfusion SPECT software. Methods: The processing starts with the extraction of the morphologic skeleton of the left ventricular myocardium from reconstructed transverse sections. Fuzzy logic is used to decide whether a pixel belongs to the myocardium and any perfusion defect is filled according to a truncated bullet model. The resulting image is partitioned in 18 isovolumetric sectors. Sex-matched normal limits, criteria of abnormality for rest 201Tl and 99mTc-labeled perfusion tracers, reproducibility studies, and detection of coronary artery disease were developed and validated in an overall population of 343 patients. The sex- and tracer-matched means and SDs of a normal response were calculated in 93 male and 93 female patients with a <5% likelihood of coronary artery disease. Reproducibility measurements and assignment of different sectors of the myocardium to a specific coronary were performed from data collected in 49 and 60 patients, respectively. The accuracy of the detection of a coronary artery occlusion was assessed in 48 patients who also underwent coronary angiography. Results: The intra- and interoperator reproducibility of the sectorial activity was high with a linear regression coefficient of 0.97 and a SD of the difference measurement at 4.4% and 3.8%, respectively. Overall sensitivity and specificity for the detection of occluded coronary artery were 90% and 80%, respectively. For the detection of left anterior descending, left circumflex, and right artery coronary occlusion, sensitivity was 92%, 75%, and 92.5%, respectively, and specificity was 75%, 78%, and 90%, respectively. Conclusion: The new quantitative myocardial perfusion SPECT software appears to be a very helpful program for the objective analysis of perfusion tracer distribution in myocardial SPECT and a very accurate tool in the detection and localization of coronary artery occlusion.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010195407ZK.pdf 1202KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:2次