Osami Sugawa2  Yasushi Oka1  Iichi Ogahara2  Kunio Kawagoe2 
[1] Department of Architecture, Science University of Tokyo, Japan;Center for Fire Science and Technology, Science University of Tokyo, Japan
关键词: Ghosting fire;    Poorly ventilation;    Compartment fire;    Detached flame;    Flammability limit;   
DOI  :  10.3210/fst.9.2_5
学科分类:环境科学(综合)
来源: Tokyo University of Science * Center for Fire Science and Technology for Building
PDF
【 摘 要 】

References(7)Cited-By(15)We have investigated fire behavior in a poorly ventilated compartment using a methyl alchol pool fire of 30cmφ as a source in a box of 2m(W) ×3m(L) ×0.6m(H). Temperatures, gas concentrations of CO, CO2, O2, and methyl alcohol vapor, fuel consumption rate, and air exchange rate were measured simultaneously. The level of the fuel surface was kept constant during the tests by means of automatic fuel supply system. The flame began to detach from the fuel surface as the oxygen concentration decreased to about 6 vol. %, it color then bocoming pale blue. The flame later detached from the fuel surface and a "ghosting flame" was observed for 20-40min. In the poorly ventilated burning conditions, it was revealed that the air exchange rate was about 5 litters/sec, oxygen concentration was about 13-14 vol. %, and the burning rate was about 0.3-0.33 g/sec which was almost 1/5 of the normal burning rate. Based on the O2, and CO2 concentrations and air exchange rate, the fuel comsumption rate was estimated and which corresponded to the consumption rate measured. It was found that three times of the stoichiometrically required ventilation was occurred in the ghosting period and it ensured complete combustion of methyl alcohol.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201911300906057ZK.pdf 1039KB PDF download