期刊论文详细信息
Journal of Veterinary Medical Science
New Visible Endotracheal Intubation Method Using the Endoscope System for Mice Inhalational Anesthesia
Naoki ITANO5  Kyoko SHIOYA3  Noriyuki KASAI1  Kenjiro KONNO4  Teppei OGAWA2  Mika HATAKEYAMA6 
[1] Center for Laboratory of Animal Research, Tohoku University, 2�?1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980�?8575, Japan;NATSUME SEISAKUSHO Co., Ltd., 7�?18 Saitoasagi-7, Ibaraki-shi Osaka 567�?0085, Japan;Laboratory of Animal Experiment and Medicine Management, National Cerebral and Cardiovascular Center, 5�?7�?1 Fujishiro-dai, Suita, Osaka 565�?8565, Japan;Department of Animal Medical Sciences, Faculty of Life Sciences, Kyoto Sangyo University, Kamigamo, Kita-ku, Kyoto 603�?8555, Japan;Department of Molecular Biosciences, Faculty of Life Sciences, Kyoto Sangyo University, Kamigamo, Kita-ku, Kyoto 603�?8555, Japan;AVS Co., Ltd., Shinjuku San-ei Bldg. 5th Fl., 1�?22�?2 Nishi-Shinjuku, Shinjuku-ku, Tokyo 160�?0023, Japan
关键词: 3Rs;    anesthesia;    endoscope;    intubation;    mouse;   
DOI  :  10.1292/jvms.13-0647
学科分类:兽医学
来源: Japanese Society of Veterinary Science
PDF
【 摘 要 】

References(22)Cited-By(1)Appropriate and effective anesthesia is critical, because it has a strong influence on laboratory animals, and its affect greatly impacts the experimental data. Inhalational anesthesia by endotracheal intubation is currently prevailing in general anesthesia and is prefered over injection anesthesia, especially for large laboratory animals, because it is a safe and easy control agent. However, it is not common for small laboratory animals, because of the high degree of technical skills required. We assessed the capability of use for mice of the endotracheal intubation by using the endoscope system “TESALA AE-C1�? and inhalational anesthesia using a ventilator. Endotracheal intubation was successfully performed on all 10 C57BL/6 mice injected with M/M/B: 0.3/4/5 comprised of medetomidine, midazoram and butorphanol, at a dose of 0.3 mg/kg + 4.0 mg/kg + 5.0 mg/kg body weight/mouse, respectively. After the intubated mice were connected with the inhalational anesthesia circuit and the ventilator, vital signs were measured until 15 min after the connection. The data with M/M/B: 0.3/4/5 showed stable and normal values, which indicated that this new endotracheal intubation method was simple, reliable and safe, which mean that this anesthesia is favorable in regard to the animal’s welfare.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201911300061458ZK.pdf 888KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:10次