Vernier effect of cascaded dual microring sensor
C Y ZHAO^1,21  J X LIAO^12 
[1] 1College of Science, Hangzhou Dianzi University, Zhejiang 310018, China^1;State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Opto-Electronics, Shanxi University, Taiyuan 030006, China^2
关键词: Integrated optics;    microring sensor;    Vernier effect;    measurement range;   
DOI  :  
学科分类:物理(综合)
来源: Indian Academy of Sciences
PDF
【 摘 要 】

We demonstrate a Vernier microring sensor consisting of a traditional cascaded dual microring resonator and an additional measurement range unit. The sensor’s performance is simulated for different concentrations of aqueous solutions of ethylene glycol ($\rm{C_{2}H_{6}O_{2}}$). The theoretical sensitivity of our system is as high as 7386 nm/RIU, an order of magnitude much larger than that of the traditional cascaded dual microring sensor (562 nm/RIU), 13.1 times more than the traditional cascaded dual microring sensor. At the same time, the measurement range can reach as high as $2.49 × 10^{−2}$ RIU.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910257281189ZK.pdf 1696KB PDF download