Optimization in the Design and Fabrication of a PZT Piezoelectric Micromachined Ultrasound Transducer (PMUT)
Puers, Robert1  Sadeghpour, Sina2 
[1] Author to whom correspondence should be addressed.;Department of Electrical Engineering (ESAT-MICAS), KU Leuven, 3001 Leuven, Belgium
关键词: lead zirconate titanate (PZT);    Crystal orientation;    XRD;    PMUT;   
DOI  :  10.3390/proceedings2130743
学科分类:社会科学、人文和艺术(综合)
来源: mdpi
PDF
【 摘 要 】

This paper presents an optimized way of lead zirconate titanate (PZT) deposition in orderto selectively grow three different (100/001), (110), and (111) crystal orientation in two differentthickness ranges, thinner and thicker than 400 nm. The thickness of the PZT layer is also optimizedto not diminish the generated bending moment more than 10%. A 1μm PZT layer with (100/001)dominant crystal orientation and highly columnar crystal structure is deposited and used in thefabrication of a circular PMUT. The PMUT has a 410 μm diameter and resonates at 462 kHz withthe displacement of 1200 nm/V.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910257266448ZK.pdf 774KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:13次