期刊论文详细信息
The Journal of Thoracic and Cardiovascular Surgery
An intraoperative test device for aortic valve repair
Sebastian Berra1  Ignacio G. Berra2  Peter E. Hammer3  Alfredo Oscar Irusta4  Seok Chang Ryu5 
[1] Catedra de control, Universidad de Buenos Aires, Ciudad Autonoma de Buenos Aires, Argentina;Cirugia cardiovascular, Hospital Nacional de Pediatria J. P. Garrahan, Ciudad Autonoma de Buenos Aires, Argentina;Department of Cardiac Surgery, Boston Children's Hospital, Boston, Mass;Lew insumos e Innovaciones S.A., Moron, Buenos Aires, Argentina;Mechanical Engineering, Texas A&M University, College Station, Tex
关键词: aortic valve repair;    device;    pressurize;    viewer;   
DOI  :  10.1016/j.jtcvs.2018.07.113
学科分类:心脏病和心血管学
来源: Mosby, Inc.
PDF
【 摘 要 】

ObjectiveAortic valve repair is currently in transition from surgical improvisation to a reproducible operation and an option for many patients with aortic regurgitation. Our research efforts at improving reproducibility include development of methods for intraoperatively testing and visualizing the valve in its diastolic state.MethodsWe developed a device that can be intraoperatively secured in the transected aorta allowing the aortic root to be pressurized and the closed valve to be inspected endoscopically. Our device includes a chamber that can be pressurized with crystalloid solution and ports for introduction of an endoscope and measuring gauges. We show use of the device in explanted porcine hearts to visualize the aortic valve and to measure leaflet coaptation height in normal valves and in valves that have undergone valve repair procedures.ResultsThe procedure of introducing and securing the device in the aorta, pressurizing the valve, and endoscopically visualizing the closed valve is done in less than 1 minute. The device easily and reversibly attaches to the aortic root and allows direct inspection of the aortic valve under conditions that mimic diastole. It enables the surgeon to intraoperatively study the valve immediately before repair to determine mechanisms of incompetence and immediately after the repair to assess competence. We also show its use in measuring valve leaflet coaptation height in the diastolic state.ConclusionsThis device enables more relevant prerepair valve assessment and also enables a test of postrepair valve competence under physiological pressures.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201910255264816ZK.pdf 1242KB PDF download
  文献评价指标  