Safety and efficacy of fiducial marker implantation for robotic stereotactic body radiation therapy with fiducial tracking
  1    2    2    2    2    2    2    2    2    2    2    3    3    3    3 
[1] 0000000419368956, grid.168010.e, Department of Statistical Analysis, Radiation Oncology, Stanford University School of Medicine, 875 Blake Wilbur Drive, California, USA;Hartmann Radiotherapy Institute, Levallois-Perret, 4 rue Kleber, Levallois-Perret, France;Hartmann Radiotherapy Institute, Levallois-Perret, 4 rue Kleber, Levallois-Perret, France;Rafael Institute, Center for Predictive Medicine, 3 boulevard Bineau, Levallois-Perret, France;
关键词: Stereotactic body radiation therapy;    Image guided radiation therapy;    Fiducial marker;   
DOI  :  10.1186/s13014-019-1373-2
来源: publisher
PDF
【 摘 要 】

PurposeThe purpose of this study was to assess the feasibility, efficacy and toxicity of fiducial marker implantation and tracking in CyberKnife® stereotactic radiation therapy (SBRT) applied to extracranial locations.Materials and methodThis is a retrospective, single-centre, observational study to collect the data of all patients treated by stereotactic radiation therapy with fiducial marker tracking at extracranial locations, conducted between June 2014 and November 2017. Information regarding the implantation procedure, the types of toxicity related to marker implantation and the number of markers implanted/tracked during treatment were collected. Complication rates were evaluated using the CTCAE v4 [Common Terminology Criteria for Adverse Events] scale. The technical success rate was based on the ability to optimally track the tumor throughout all treatment fractions.ResultsOut of 2505 patients treated by stereotactic radiation therapy, 25% received treatment with fiducial marker tracking. The total number of implantation procedures was 616 and 1543 fiducial markers were implanted. The implantation-related complication rate was 3%, with 16 Grade 1 events and 4 Grade 2 events. The number of treated patients and the number of implanted markers has gradually increased since the technique was first implemented. The median treatment time was 27 min (range 10–76). 1295 fiducials were effectively tracked throughout all treatment fractions, corresponding to a technical success rate of 84%. The difference between the number of fiducials implanted and those tracked during treatment decreased significantly as the site’s experience increased.ConclusionFiducial marker implantation and tracking is feasible, well-tolerated, and technically effective technique in SBRT for extracranial tumors.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910106287889ZK.pdf 692KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:44次