会议论文详细信息
7th International Conference on 3D Radiation Dosimetry | |
Stereotactic body radiation therapy delivery validation | |
Olding, T.^1 ; Garcia, L.^1 ; Alexander, K.^2 ; Schreiner, L.J.^1,2 ; Joshi, C.^1,2 | |
Cancer Centre of South Eastern Ontario, Kingston General Hospital, 25 King Street West, Kingston, ON K7L5P9, Canada^1 | |
Department of Physics, Queen's University, Kingston, ON K7L3N6, Canada^2 | |
关键词: Electronic portal imaging devices; Gel measurement; Stereotactic body radiation therapy; Treatment plans; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/444/1/012073/pdf DOI : 10.1088/1742-6596/444/1/012073 |
|
来源: IOP | |
![]() |
【 摘 要 】
This work describes the use of a motion phantom and 1D, 2D, and 3D ion chamber, EBT3 film, electronic portal imaging device (EPID) and FXG gel measurements for dosimetric validation of a stereotactic ablative radiation therapy (SBRT) technique in our clinic. Results show good agreement between the measurements and calculated treatment plan dose.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|