期刊论文详细信息
BioMedical Engineering OnLine
Real-time algorithm for Poissonian noise reduction in low-dose fluoroscopy: performance evaluation
  1    1    1    2    2    2    3 
[1] 0000 0001 0790 385X, grid.4691.a, Department of Electrical Engineering and Information Technologies, Università di Napoli “Federico II”, Via Claudio, 21, 80125, Naples, Italy;0000 0001 0790 385X, grid.4691.a, Department of Electrical Engineering and Information Technologies, Università di Napoli “Federico II”, Via Claudio, 21, 80125, Naples, Italy;Istituti Clinici Scientifici Maugeri S.p.A.—Società Benefit, Via S. Maugeri, 4, 27100, Pavia, Italy;0000 0001 0790 385X, grid.4691.a, Università di Napoli, “Federico II”, dip. di Fisica “E. Pancini” & INFN sez. di Napoli, Via Cintia, 80126, Naples, Italy;
关键词: Fluoroscopy;    Quantum noise;    Video denoising;    Real-time processing;    X-ray dose reduction;    NVCA;    VBM4D;   
DOI  :  10.1186/s12938-019-0713-7
来源: publisher
PDF
【 摘 要 】

BackgroundQuantum noise intrinsically limits the quality of fluoroscopic images. The lower is the X-ray dose the higher is the noise. Fluoroscopy video processing can enhance image quality and allows further patient’s dose lowering. This study aims to assess the performances achieved by a Noise Variance Conditioned Average (NVCA) spatio-temporal filter for real-time denoising of fluoroscopic sequences. The filter is specifically designed for quantum noise suppression and edge preservation. It is an average filter that excludes neighborhood pixel values exceeding noise statistic limits, by means of a threshold which depends on the local noise standard deviation, to preserve the image spatial resolution. The performances were evaluated in terms of contrast-to-noise-ratio (CNR) increment, image blurring (full width of the half maximum of the line spread function) and computational time. The NVCA filter performances were compared to those achieved by simple moving average filters and the state-of-the-art video denoising block matching-4D (VBM4D) algorithm. The influence of the NVCA filter size and threshold on the final image quality was evaluated too.ResultsFor NVCA filter mask size of 5 × 5 × 5 pixels (the third dimension represents the temporal extent of the filter) and a threshold level equal to 2 times the local noise standard deviation, the NVCA filter achieved a 10% increase of the CNR with respect to the unfiltered sequence, while the VBM4D achieved a 14% increase. In the case of NVCA, the edge blurring did not depend on the speed of the moving objects; on the other hand, the spatial resolution worsened of about 2.2 times by doubling the objects speed with VBM4D. The NVCA mask size and the local noise-threshold level are critical for final image quality. The computational time of the NVCA filter was found to be just few percentages of that required for the VBM4D filter.ConclusionsThe NVCA filter obtained a better image quality compared to simple moving average filters, and a lower but comparable quality when compared with the VBM4D filter. The NVCA filter showed to preserve edge sharpness, in particular in the case of moving objects (performing even better than VBM4D). The simplicity of the NVCA filter and its low computational burden make this filter suitable for real-time video processing and its hardware implementation is ready to be included in future fluoroscopy devices, offering further lowering of patient’s X-ray dose.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910104781968ZK.pdf 1552KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:8次