Rapid Discrimination of Malignant Breast Lesions from Normal Tissues Utilizing Raman Spectroscopy System: A Systematic Review and Meta-Analysis of In Vitro Studies
Ke Deng1  Yue Xiao1  Xuelei Ma1  Hongyuan Jia1  Zhigong Wei1  Chenjing Zhu1  Jing Xu2 
[1] State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan, PR China;West China Hospital, Sichuan University, Chengdu, Sichuan, PR China
关键词: Cancer detection and diagnosis;    Meta-analysis;    Absorption spectroscopy;    Raman spectroscopy;    Breast cancer;    Lasers;    Principal component analysis;    Lesions;   
DOI  :  10.1371/journal.pone.0159860
学科分类:医学(综合)
来源: Public Library of Science
PDF
【 摘 要 】

Purpose The aim of this study is to evaluate the diagnostic accuracy of Raman spectroscopy system in the detection of malignant breast lesions through a systemic review and meta-analysis of published studies. Methods We conducted a comprehensive literature search of PubMed and Embase from 2000 to June 2015. Published studies that evaluated the diagnostic performance of Raman spectroscopy in distinguishing malignant breast lesions from benign lesions and normal tissues were included in our study. The pooled sensitivity, specificity, diagnostic odds ratio, and the area under the curve of summary receiver-operating characteristic curves was derived. A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies guidelines was used to assess the quality of included studies. Results The initial search produced a total of 157 articles after removing duplicates. Nine studies (8 in vitro and 1 in vivo) were eligible in this meta-analysis. We analyzed the eight in vitro studies with 1756 lesions, the pooled sensitivity and specificity of Raman spectroscopy system for the diagnosis of malignant breast lesions were 0.92 (95% CI 0.86–0.96) and 0.97 (97% CI 0.93–0.98), respectively. Diagnostic odds ratio was 266.70 (95% CI 89.38–795.79), and the area under the curve of summary receiver-operating characteristic curves was 0.98 (95% CI 0.97–0.99). Significant heterogeneity was found between studies. There was no evidence of considerable publication bias. Conclusions Raman spectroscopy system is an optical diagnostic technology with great value for detecting malignant breast lesions. At the same time, it has advantages of being non-invasive, real-time, and easy to use. Thus it deserves to be further explored for intra-operatory breast tumor margin detection.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201904027667748ZK.pdf 1645KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:10次