| Archives of Metallurgy and Materials | |
| Influence of Direct Thermal Analysis Experimental Conditions on Determination of the High Temperature Phase Transformation Temperatures / Wpływ Warunków Prowadzenia Bezpośredniej Analizy Termicznej Na Określenie Temperatur Wysoko Temperaturowych Przemian Fazowych | |
| K. Gryc1  M. Strouhalová1  L. Socha1  K. Michalek1  B. Smetana2  | |
| [1] VŠB-Technical University of Ostrava , Faculty of Metallurgy and Materials Engineering, Department of Metallurgy and Foundry , and Regional Materials Science and Technology Centre, 17. Listo padu 15/2172, Ostrava -Poruba, Czech Republic;VŠB-Technical University of Ostrava , Faculty of Metallurgy and Materials Engineering, Department of Physical Chemistry and Theory of Technological Processes, and Regional Materials Science and Technology Centre, 17. Listo padu 15/2172, Ostrava -Poruba, Czech Republic | |
| 关键词: Keywords: nickel; melting/solidification point temperature; direct thermal analysis; heating/cooling rate; sample mass; | |
| DOI : 10.1515/amm-2015-0458 | |
| 学科分类:金属与冶金 | |
| 来源: Akademia Gorniczo-Hutnicza im. Stanislawa Staszica / University of Mining and Metallurgy | |
PDF
|
|
【 摘 要 】
Thermo-physical and thermodynamic properties of metallic systems represent some of the most important data that allows to describe their behaviour under strictly specified conditions. These data are the basic, input data for simulative programs, which can model this behaviour and they can be applied to real conditions. Method of direct thermal analysis is the one of the methods of enabling to obtain such data. This paper deals with application of this method on particular sample of pure standard material. The experimental laboratory system for thermal analysis Netzsch STA 449 F3 Jupiter was used for experimental measurements. This paper is studying the influence of experimental conditions on the obtained temperature of phase transformations and on shift of phase transformation temperatures with respect to the monitored experimental conditions, accuracy and credibility of the measured data. Acquired values of this data could be significantly influenced by experimental conditions, size (mass) of samples, purity of inert atmosphere and also by regimes of controlled heating and cooling rates.
【 授权许可】
Unknown
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201902180622030ZK.pdf | 472KB |
PDF