Cardiovascular and Thoracic Open | |
Treatment of porcine bioprosthetic mitral valve thrombosis with anticoagulation: | |
Masaki Hamamoto1  | |
关键词: Anticoagulation; mitral valve; porcine bioprosthesis; thrombosis; | |
DOI : 10.1177/2055552016652973 | |
学科分类:医学(综合) | |
来源: Sage Journals | |
【 摘 要 】
A 70-year-old man underwent mitral valve replacement using a porcine bioprosthesis for infective endocarditis. Transthoracic echocardiography revealed thickened leaflets with increased transprosthetic pressure gradient and new regurgitation, 6âmonths after surgery. He was followed up medically with the diagnosis of early valve degeneration. He ultimately presented with worsening orthopnea 13âmonths after surgery. Transesophageal echocardiography revealed an immobile round mass attached to the ventricular aspect of the leaflets, which hampered valve opening, suggesting bioprosthetic valve thrombosis. Anticoagulation with heparin and warfarin were effective and transthoracic echocardiography showed normal transprosthetic pressure gradient and disappearance of regurgitation 2âmonths later.
【 授权许可】
CC BY-NC
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201902020763923ZK.pdf | 138KB | download |