【 摘 要 】
Background
To be less resource intensive, we developed a template-based breast IMRT technique (TB-IMRT). This study aims to compare resources and dose distribution between TB-IMRT and conventional breast radiation (CBR).
Methods
Twenty patients with early stage breast cancer were planned using CBR and TB-IMRT. Time to plan, coverage of volumes, dose to critical structures and treatment times were evaluated for CBR and TB-IMRT. Two sided-paired t tests were used.
Results
TB-IMRT planning time was less than CBR (14.0 vs 39.0 min, p < 0.001). Fifteen patients with CBR needed 18 MV, and 11 of these were planned successfully with TB-IMRT using 6 MV. TB-IMRT provided better homogeneity index (0.096 vs 0.124, p < 0.001) and conformity index (0.68 vs 0.59, p = 0.003). Dose to critical structures were comparable between TB-IMRT and CBR, and treatment times were also similar (6.0 vs 7.8 min, p = 0.13).
Conclusions
TB- IMRT provides reduction of planning time and minimizes the use of high energy beams, while providing similar treatment times and equal plans compared to CBR. This technique permits efficient use of resources with a low learning curve, and can be done with existing equipment and personnel.
【 授权许可】
2013 Nguyen et al.; licensee BioMed Central Ltd.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
20150407103952193.pdf | 221KB | download | |
Figure 1. | 125KB | Image | download |
【 图 表 】
Figure 1.
【 参考文献 】
- [1]Early Breast Cancer Trialists' Collaborative Group: Effects of radiotherapy and surgery in early breast cancer. An overview of the randomized trials. N Engl J Med 1995, 333:1444-1455.
- [2]Clarke M, Collins R, Darby S, Davies C, Elphinstone P, Evans E: Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trials. Lancet 2005, 366:2087-2106.
- [3]Vicini FA, Sharpe M, Kestin L, Martinez A, Mitchell CK, Wallace MF: Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys 2002, 54:1336-1344.
- [4]Hong L, Hunt M, Chui C, Spirou S, Forster K, Lee H: Intensity-modulated tangential beam irradiation of the intact breast. Int J Radiat Oncol Biol Phys 1999, 44:1155-1164.
- [5]Ahunbay EE, Chen GP, Thatcher S, Jursinic PA, White J, Albano K: Direct aperture optimization-based intensity-modulated radiotherapy for whole breast irradiation. Int J Radiat Oncol Biol Phys 2007, 67:1248-1258.
- [6]Pignol JP, Olivotto I, Rakovitch E, Gardner S, Sixel K, Beckham W: A multicenter randomized trial of breast intensity-modulated radiation therapy to reduce acute radiation dermatitis. J Clin Oncol 2008, 26:2085-2092.
- [7]Donovan E, Bleakley N, Denholm E, Evans P, Gothard L, Hanson J: Randomised trial of standard 2D radiotherapy (RT) versus intensity modulated radiotherapy (IMRT) in patients prescribed breast radiotherapy. Radiother Oncol 2007, 82:254-264.
- [8]Smith BD, Pan IW, Shih YC, Smith GL, Harris JR, Punglia R: Adoption of intensity-modulated radiation therapy for breast cancer in the United States. J Natl Cancer Inst 2011, 103:798-809.
- [9]van der Laan HP, Hurkmans CW, Kuten A, Westenberg HA: Current technological clinical practice in breast radiotherapy; results of a survey in EORTC-radiation oncology group affiliated institutions. Radiother Oncol 2010, 94:280-285.
- [10]Shaw E, Kline R, Gillin M, Souhami L, Hirschfeld A, Dinapoli R: Radiation therapy oncology group: radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys 1993, 27:1231-1239.
- [11]van't Riet A, Mak AC, Moerland MA, Elders LH, van der Zee W: A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate. Int J Radiat Oncol Biol Phys 1997, 37:731-736.
- [12]Ansbacher W: Three-dimensional portal image-based dose reconstruction in a virtual phantom for rapid evaluation of IMRT plans. Med Phys 2006, 33:3369-3382.
- [13]Mayo CS, Urie MM, Fitzgerald TJ: Hybrid IMRT plans–concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time. Int J Radiat Oncol Biol Phys 2005, 61:922-932.
- [14]Barnett GC, Wilkinson JS, Moody AM, Wilson CB, Twyman N, Wishart GC: Randomized controlled trial of forward-planned intensity modulated radiotherapy for early breast cancer: interim results at 2 years. Int J Radiat Oncol Biol Phys 2012, 82:715-723.
- [15]Schubert LK, Gondi V, Sengbusch E, Westerly DC, Soisson ET, Paliwal BR: Dosimetric comparison of left-sided whole breast irradiation with 3DCRT, forward-planned IMRT, inverse-planned IMRT, helical tomotherapy, and topotherapy. Radiother Oncol 2011, 100:241-246.
- [16]Descovich M, Fowble B, Bevan A, Schechter N, Park C, Xia P: Comparison between hybrid direct aperture optimized intensity-modulated radiotherapy and forward planning intensity-modulated radiotherapy for whole breast irradiation. Int J Radiat Oncol Biol Phys 2010, 76:91-99.
- [17]Fong A, Bromley R, Beat M, Vien D, Dineley J, Morgan G: Dosimetric comparison of intensity modulated radiotherapy techniques and standard wedged tangents for whole breast radiotherapy. J Med Imaging Radiat Oncol 2009, 53:92-99.
- [18]Farace P, Zucca S, Solla I, Fadda G, Durzu S, Porru S: Planning hybrid intensity modulated radiation therapy for whole-breast irradiation. Int J Radiat Oncol Biol Phys 2012, 84:e115-e122.
- [19]Smith W, Menon G, Wolfe N, Ploquin N, Trotter T, Pudney D: IMRT for the breast: a comparison of tangential planning techniques. Phys Med Biol 2010, 55:1231-1241.
- [20]Chau RM, Leung SF, Kam MK, Cheung KY, Kwan WH, Yu KH: A broadly adaptive array of dose-constraint templates for planning of intensity-modulated radiation therapy for advanced T-stage nasopharyngeal carcinoma. Int J Radiat Oncol Biol Phys 2009, 74:21-28.
- [21]Taira S, Hizume M, Note I, Sugimoto J, Okita R: A template for forward planning in prostate cancer treatment: conformal irradiation with segmental intensity-modulation. Igaku Butsuri 2003, 23:59-64.