| Thrombosis Journal | |
| Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study | |
| Walter A Wuillemin9  Dimitrios A Tsakiris1  Hans Stricker6  Guido Reber7  Adriana Mendez4  Wolfgang Korte2  Lars M Asmis5  Anne Angelillo-Scherrer3  Lorenzo Alberio1,11  Lucas M Bachmann8  Michael Nagler1,10  | |
| [1] Diagnostic Hematology, University Hospital of Basel, Basel CH-4031, Switzerland;Institute for Clinical Chemistry and Hematology, Cantonal Hospital St Gallen, St Gallen CH-9007, Switzerland;Service and Central Laboratory of Hematology, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne CH-1011, Switzerland;Center for Laboratory Medicine, Cantonal Hospital Aarau, Aarau CH-5001, Switzerland;Unilabs Zurich, Zurich CH-8034, Switzerland;Division of Surgery, Regional Hospital La Carita, Locarno CH-6600, Switzerland;Laboratory for Special Hemostasis, University Hospital of Geneva, Geneva CH-1211, Switzerland;Medignition Inc, Zug CH-6300, Switzerland;University of Berne, Berne CH-3000, Switzerland;Division of Hematology and Central Hematology Laboratory, Luzerner Kantonsspital, Lucerne 16 CH-6000, Switzerland;Department of Hematology and Central Hematology Laboratory, Inselspital University Hospital and University of Berne, Berne CH-3010, Switzerland | |
| 关键词: Test validity; Reproducibility of testing; Intraclass correlation coefficient; Inter-rater variability; | |
| Others : 838638 DOI : 10.1186/1477-9560-11-6 |
|
| received in 2012-11-30, accepted in 2013-02-13, 发布年份 2013 | |
PDF
|
|
【 摘 要 】
Background
While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test.
Methods
Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA.
Results
The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC’s ranged from 0.04 (FII) to 0.93 (FVIII).
Conclusions
Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
【 授权许可】
2013 Nagler et al; licensee BioMed Central Ltd.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20140716022722272.pdf | 183KB |
【 参考文献 】
- [1]Marshall WJ, Bangert SK, Lapsley M: The clinical utility of laboratory investigations. In Clinical Chemistry. Philadelphia, PA: Mosby Elsevier; 2012:9. volume 7
- [2]NCCLS: Evaluation of Precision Performance of Clinical Chemistry Devices; Approved Guideline. Wayne, PA: NCCLS; 1999.
- [3]Miller WG, Jones GR, Horowitz GL, Weykamp C: Proficiency testing/external quality assessment: current challenges and future directions. Clin Chem 2011, 57:1670-1680.
- [4]Spannagl M, Dick A, Reinauer H: External quality assessment schemes in coagulation in Germany: between regulatory bodies and patient outcome. Semin Thromb Hemost 2007, 33:259-264.
- [5]Plebani M, Sanzari MC, Zardo L: Quality control in coagulation testing. Semin Thromb Hemost 2008, 34:642-646.
- [6]Cuker A, Raby A, Moffat KA, Flynn G, Crowther MA: Interlaboratory variation in heparin monitoring: Lessons from the Quality Management Program of Ontario coagulation surveys. Thromb Haemost 2010, 104:837-844.
- [7]Favaloro EJ, Bonar R, Kershaw G, Duncan E, Sioufi J, Marsden K: Investigations from external quality assurance programs reveal a high degree of variation in the laboratory identification of coagulation factor inhibitors. Semin Thromb Hemost 2009, 35:794-805.
- [8]Meijer P, Haverkate F: External quality assessment and the laboratory diagnosis of thrombophilia. Semin Thromb Hemost 2005, 31:59-65.
- [9]Shahangian S, Labeau KM, Howerton DA: Prothrombin time testing practices: adherence to guidelines and standards. Clin Chem 2006, 52:793-794.
- [10]Asmis LM, Alberio L, Angelillo-Scherrer A, Korte W, Mendez A, Reber G, Seifert B, Stricker H, Tsakiris DA, Wuillemin WA: Rivaroxaban: Quantification by anti-FXa assay and influence on coagulation tests: a study in 9 Swiss laboratories. Thromb Res 2012, 129:492-498.
- [11]Banfi G, Del Fabbro M: Biological variation in tests of hemostasis. Semin Thromb Hemost 2009, 35:119-126.
- [12]Institute CaLS: On-stage prothrombin time (PT) test and activated partial thromboplastin time (APTT) test. In CLSI Document H47–A2. Wayne, PA: CLSI; 2008.
- [13]Thomson JM, Taberner DA, Poller L: Automation and prothrombin time: a United Kingdom field study of two widely used coagulometers. J Clin Pathol 1990, 43:679-684.
- [14]Jennings I, Kitchen DP, Woods TA, Kitchen S, Walker ID, Preston FE: Laboratory performance in the World Federation of Hemophilia EQA programme, 2003–2008. Haemophilia 2009, 15:571-577.
- [15]Meijer P, Haverkate F: An external quality assessment program for von Willebrand factor laboratory analysis: an overview from the European concerted action on thrombosis and disabilities foundation. Semin Thromb Hemost 2006, 32:485-491.
- [16]Kitchen S, Jennings I, Woods TA, Kitchen DP, Walker ID, Preston FE: Laboratory tests for measurement of von Willebrand factor show poor agreement among different centers: results from the United Kingdom National External Quality Assessment Scheme for Blood Coagulation. Semin Thromb Hemost 2006, 32:492-498.
- [17]Cuker A, Ptashkin B, Konkle BA, Pipe SW, Whinna HC, Zheng XL, Cines DB, Pollak ES: Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor Xa-correlated activated partial thromboplastin time. J Thromb Haemost 2009, 7:80-86.
- [18]Tripodi A, Chantarangkul V: Performance of quantitative D-dimer methods: results of the Italian external quality assessment scheme. J Thromb Haemost 2007, 5:184-185.
- [19]Meijer P, Verbruggen B: The between-Laboratory Variation of Factor VIII Inhibitor Testing: The Experience of the External Quality Assessment Program of the ECAT Foundation. Semin Thromb Hemost 2009, 35:786-793.
- [20]Kitchen S, Jennings I, Preston FE, Kitchen DP, Woods TA, Walker ID: Interlaboratory variation in factor VIII:C inhibitor assay results is sufficient to influence patient management: data from the UK national quality external assessment scheme for blood coagulation. Semin Thromb Hemost 2009, 35:778-785.
- [21]Favaloro EJ, Bonar R, Kershaw G, Mohammed S, Duncan E, Marsden K, Committee RHQH: Laboratory identification of factor VIII inhibitors in the real world: the experience from Australasia. Haemophilia 2010, 16:662-670.
- [22]Cunningham MT, Olson JD, Chandler WL, Van Cott EM, Eby CS, Teruya J, Hollensead SC, Adcock DM, Allison PM, Kottke-Marchant KK, Smith MD: External quality assurance of fibrinogen assays using normal plasma: results of the 2008 College of American Pathologists proficiency testing program in coagulation. Arch Pathol Lab Med 2008, 2012(136):789-795.
- [23]Jennings I, Kitchen DP, Woods T, Kitchen S, Walker ID: Differences between multifibrin U and conventional Clauss fibrinogen assays: data from UK National External Quality Assessment Scheme surveys. Blood Coagul Fibrinolysis 2009, 20:388-390.
- [24]Tripodi A, Chantarangkul V, Legnani C, Fronton R, Testa S: Discrepancy of the international normalized ratio observed in the external quality assessment survey: a cause for concern. J Thromb Haemost 2012, 10:714-716.
- [25]van den Besselaar AM, Haas FJ, van der Graaf F, Kuypers AW: Harmonization of fibrinogen assay results: study within the framework of the Dutch project ‘Calibration 2000’. Int J Lab Hematol 2009, 31:513-520.
PDF