期刊论文详细信息
BMC Veterinary Research
Reliability of quantitative echocardiography in adult sheep and goats
I Mark Bowen2  Timothy J Potter1  Gayle D Hallowell2 
[1] Westpoint Veterinary Group, Dawes Farm, Bognor Road, Warnham, West Sussex, RH12 3SH, UK;School of Veterinary Medicine and Science, University of Nottingham, Sutton Bonington, Leicestershire, LE12 5RD, UK
关键词: Ultrasonography;    Measurements;    Heart;    Cardiac;    Caprine;    Ovine;   
Others  :  1119706
DOI  :  10.1186/1746-6148-8-181
 received in 2012-08-01, accepted in 2012-09-25,  发布年份 2012
PDF
【 摘 要 】

Background

Echocardiography is a non-invasive method for assessment of the ovine and caprine heart. Complete reference ranges for cardiac dimensions and time indices for both species are not currently available and reliability of these measurements has not been evaluated. The objectives for this study are to report reliability, normal cardiac dimensions and time indices in a large group of adult sheep and goats.

Fifty-one adult sheep and forty adult goats were recruited. Full echocardiographic examinations were performed in the standing unsedated animal. All animals underwent echocardiography four times in a 72-hour period. Echocardiography was performed three times by one author and once by another. Images were stored and measured offline. Technique and measurement repeatability and reproducibility and any differences due to animal or day were evaluated. Reference ranges (mean ± 2 standard deviations) were calculated for both species.

Results

Majority of the images obtained were of good to excellent quality. Image acquisition was straightforward with 5.4% of animals demonstrating a small scanning window. Reliability was excellent for majority of dimensions and time indices. There was less variation in repeatability when compared with reproducibility and differences were greater for technique than for measurements. Dimensions that were less reliable included those for right ventricular diameter and left ventricular free wall. There were many differences in cardiac dimensions between sheep and goats.

Conclusions

This study has demonstrated that specific reference ranges are required for these two species. Repeatability and reproducibility were excellent for the majority of cardiac dimensions and time indices suggesting that this technique is reliable and valuable for examination of clinical cases over time and for longitudinal research studies.

【 授权许可】

   
2012 Hallowell et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150208104519187.pdf 336KB PDF download
Figure 1. 43KB Image download
【 图 表 】

Figure 1.

【 参考文献 】
  • [1]Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, Gutgesell H, Reichek N, Sahn D, Schnittger I, et al.: Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 1989, 2(5):358-367.
  • [2]Moses BL, Ross JN Jr: M-mode echocardiographic values in sheep. Am J Vet Res 1987, 48(9):1313-1318.
  • [3]Dancea A, Fouron JC, Miro J, Skoll A, Lessard M: Correlation between electrocardiographic and ultrasonographic time-interval measurements in fetal lamb heart. Pediatr Res 2000, 47(3):324-328.
  • [4]Kirberger RM, van den Berg JS: Pulsed wave Doppler echocardiographic evaluation of intracardiac blood flow in normal sheep. Res Vet Sci 1993, 55(2):189-194.
  • [5]Veille JC, Sivakoff M, Nemeth M: Accuracy of echocardiography measurements in the fetal lamb. Am J Obstet Gynecol 1988, 158(5):1225-1232.
  • [6]Hong T, Maish MS, Cohen J, Fitzpatrick P, Bert AA, Harper JS 3rd, Fang D, Hoffman-Kim D, Hopkins RA: Reproducible echocardiography in juvenile sheep and its application in the evaluation of a pulmonary valve homograft implant. Contemp Top Lab Anim Sci 2000, 39(5):20-25.
  • [7]Olsson K, Hansson A, Hydbring E, von Walter LW, Haggstrom J: A serial study of heart function during pregnancy, lactation and the dry period in dairy goats using echocardiography. Exp Physiol 2001, 86(1):93-99.
  • [8]Leroux AA, Moonen ML, Farnir F, Sandersen CF, Deleuze S, Salciccia A, Amory H: Two-dimensional and M-mode echocardiographic reference values in healthy adult Saanen goats. Vet Rec 2012, 170(6):154.
  • [9]Reef VB, McGuirk SM: Diseases of the Cardiovascular System. In Large Animal Internal Medicine. 3rd edition. Edited by BP S. St Louis: Mosby; 2002:447-468.
  • [10]Parry BW, Wrigley RH, Reuter RE: Ventricular septal defects in three familially related Saanen goats. Aust Vet J 1992, 59:72-76.
  • [11]Gardner SY, Reef VB, Palmer JE, Reimer JM, Sweeney RW: Echocardiographic diagnosis of an anomaly of the tricuspid valve in a male pygmy goat. J Am Vet Med Assoc 1992, 200(4):521-523.
  • [12]Hartley WJ, Kater JC: Perinatal disease conditions of sheep in New Zealand. N Z Vet J 1964, 12:49-57.
  • [13]Dennis SM, Leipold HW: Congenital cardiac defects in lambs. Am J Vet Res 1968, 29(12):2337-2340.
  • [14]Shivaprakesh BV, Gopalakrishna Rao D: Local anaesthetic toxicity in a sheep with patent ductus arteriosus. Indian Vet J 1997, 74:901-902.
  • [15]Bonagura JD, Herring DS, Welker F: Echocardiography. Vet Clin North Am 1985, 1(2):311-333.
  • [16]Carlsten JC: Two-dimensional echocardiography in the horse. Vet Radiol 1987, 28:76-87.
  • [17]Reef VB: Echocardiographic examination in the horse: the basics. Compend Contin Educ Pract Vet 1990, 12:1312-1319.
  • [18]Long KJ, Bonagura JD, Darke PG: Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse. Equine Vet J 1992, 24(3):226-235.
  • [19]Russel A: Body condition scoring of sheep. In Pract 1984, 6(3):91-93.
  • [20]Managing Body Condition: A Key to Successful Management. http://www.cals.ncsu.edu/an_sci/extension/animal/meatgoat/MG-BCS.htm webcite
  • [21]Sahn DJ, DeMaria A, Kisslo J, Weyman A: Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements. Circulation 1978, 58(6):1072-1083.
  • [22]Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 1977, 33:159-174.
  • [23]Yamaga T, Too K: Diagnostic ultrasound imaging of vegetative valvular endocarditis in cattle. Jap J Vet Res 1997, 35:49-63.
  • [24]Voros K, Holmes JR, Gibbs C: Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse. Equine Vet J 1991, 23(6):461-465.
  • [25]Slater JD, Herrtage ME: Echocardiographic measurements of cardiac dimensions in normal ponies and horses. Equine Vet J Suppl 1995, 19:28-32.
  • [26]Al Haidar A, Leroux AA, Borde L, Deleuze S, Cerri S, Farnir F, Sandersen CF, Amory H: Relationship between echocardiographic measurements and body size in horses. J Equine Vet Sci 2012. epub
  • [27]Hallowell GD, Potter TJ, Bowen IM: Methods and normal values for echocardiography in adult dairy cattle. J Vet Cardiol 2007, 9(2):91-98.
  • [28]Buchanan JW, Bucheler J: Vertebral scale system to measure canine heart size in radiographs. J Am Vet Med Assoc 1995, 206(2):194-199.
  • [29]Patteson MW, Gibbs C, Wotton PR, Cripps PJ: Echocardiographic measurements of cardiac dimensions and indices of cardiac function in normal adult thoroughbred horses. Equine Vet J Suppl 1995, 19:18-27.
  • [30]Terra RL: Ruminant history, Physical Examination and Records. In Large Animal Internal Medicine. 3rd edition. Edited by BP S. Missouri, USA: Mosby; 2002:3-25.
  • [31]Marr CM, Reef VB: Physiological valvular regurgitation in clinically normal young racehorses: prevalence and two-dimensional colour flow Doppler echocardiographic characteristics. Equine Vet J Suppl 1995, 19:56-62.
  • [32]Byrd BF 3rd, Finkbeiner W, Bouchard A, Silverman NH, Schiller NB: Accuracy and reproducibility of clinically acquired two-dimensional echocardiographic mass measurements. Am Heart J 1989, 118(1):133-137.
  • [33]Sampson SN, Jacobson RL, Sande RD, Susumi CJ, Larntz KJ, Tucker RL, Bayly WM: Reproducibility and repeatability of M-mode echocardiographic measurements collected from 25 normal horses. J Equine Vet Sci 1999, 19(1):51-57.
  • [34]Buhl R, Ersboll AK, Eriksen L, Koch J: Sources and magnitude of variation of echocardiographic measurements in normal standardbred horses. Vet Radiol Ultrasound 2004, 45(6):505-512.
  • [35]DeMaria AN, Neumann A, Schubart PJ, Lee G, Mason DT: Systematic correlation of cardiac chamber size and ventricular performance determined with echocardiography and alterations in heart rate in normal persons. Am J Cardiol 1979, 43(1):1-9.
  • [36]Ladipo GO, Dunn FG, Pringle TH, Bastian B, Lawrie TD: Serial measurements of left ventricular dimensions by echocardiography. Assessment of week-to-week, inter- and intraobserver variability in normal subjects and patients with valvular heart disease. Br Heart J 1980, 44(3):284-289.
  • [37]Pietro DA, Voelkel AG, Ray BJ, Parisi AF: Reproducibility of echocardiography. A study evaluating thevariability of serial echocardiographicmeasurements. Chest 1981, 79(1):29-32.
  文献评价指标  