Journal of Orthopaedic Surgery and Research | |
Effect of Poloxamer 407 as a carrier vehicle on rotator cuff healing in a rat model | |
Juneyoung Lee1  Soo-Won Chae3  Soung-Yon Kim2  | |
[1] Department of Biostatistics, Korea University College of Medicine, Anam-Dong, Seongbuk-Gu, Seoul 136-705, South Korea;Department of Orthopaedic Surgery, Hallym University Kangnam Sacred Heart Hospital, 948-1, Daerim-1 Dong, Yeongdeungpo-gu, Seoul 150-950, South Korea;Department of Mechanical Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, South Korea | |
关键词: Biomechanical testing; Histological analysis; Healing; Carrier vehicle; Rotator cuff; | |
Others : 813604 DOI : 10.1186/1749-799X-9-12 |
|
received in 2013-09-06, accepted in 2014-02-20, 发布年份 2014 | |
【 摘 要 】
Background
In vivo studies showing the effects of biologic healing-promoting factors on tendon-to-bone healing after rotator cuff repair have focused only on biologic healing-promoting factors and have not taken into consideration the effect of the carrier vehicle. Moreover, most studies have evaluated the healing process using different carrier vehicles, each of which may have specific effects on tendon healing. This may explain the large variability seen in outcomes in research studies. In this study, we investigated the effects of Poloxamer 407 as a carrier vehicle on rotator cuff healing at the repair site and compared it with those of a collagen sponge, which is a commonly used carrier vehicle.
Methods
Fifty-seven adult male Sprague–Dawley rats underwent detachment and immediate repair of the bilateral supraspinatus tendons. Rats were randomly assigned to three groups: repair only, repair with collagen sponge, and repair with Poloxamer 407. The repairs were evaluated at 1, 2, 4, and 8 weeks after surgery with histological analysis and biomechanical testing.
Results
At 4 weeks, more cellular organization, a greater number of collagen fibers, and increased maturity of collagen fibers were observed in the repair with Poloxamer 407 group than in the other groups. The repair with collagen sponge group had delayed development and collagen fiber maturation. Significant differences in the biomechanical properties were found between groups at 4 weeks. Stiffness in the case of the repair with Poloxamer 407 group was significantly higher than that in the repair with collagen sponge group. The modulus was significantly lower in the repair with collagen sponge group than in the repair only group. However, the use of Poloxamer 407 versus the collagen sponge did not significantly affect the biomechanical properties of the repaired tendons at 8 weeks.
Conclusions
Carrier vehicles may have differing effects at the early stages of rotator cuff healing. The use of Poloxamer 407 as a carrier vehicle may be useful for promoting the early stages of healing and for maintaining the initial biomechanical properties of the repaired rotator cuff tendon.
【 授权许可】
2014 Kim et al.; licensee BioMed Central Ltd.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
20140710005705866.pdf | 2077KB | download | |
Figure 8. | 67KB | Image | download |
Figure 7. | 89KB | Image | download |
Figure 6. | 91KB | Image | download |
Figure 5. | 114KB | Image | download |
Figure 4. | 114KB | Image | download |
Figure 3. | 94KB | Image | download |
Figure 2. | 58KB | Image | download |
Figure 1. | 179KB | Image | download |
【 图 表 】
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
【 参考文献 】
- [1]Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K: The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am Vol 2004, 86-A(2):219-224.
- [2]Gerber C, Fuchs B, Hodler J: The results of repair of massive tears of the rotator cuff. J Bone Joint Surg Am Vol 2000, 82(4):505-515.
- [3]Jost B, Pfirrmann CW, Gerber C, Switzerland Z: Clinical outcome after structural failure of rotator cuff repairs. J Bone Joint Surg Am Vol 2000, 82(3):304-314.
- [4]Boileau P, Brassart N, Watkinson DJ, Carles M, Hatzidakis AM, Krishnan SG: Arthroscopic repair of full-thickness tears of the supraspinatus: does the tendon really heal? J Bone Joint Surg Am Vol 2005, 87(6):1229-1240.
- [5]Jost B, Zumstein M, Pfirrmann CW, Gerber C: Long-term outcome after structural failure of rotator cuff repairs. J Bone Joint Surg Am Vol 2006, 88(3):472-479.
- [6]Juncosa-Melvin N, Boivin GP, Gooch C, Galloway MT, West JR, Dunn MG, Butler DL: The effect of autologous mesenchymal stem cells on the biomechanics and histology of gel-collagen sponge constructs used for rabbit patellar tendon repair. Tissue Eng 2006, 12(2):369-379.
- [7]Bolt P, Clerk AN, Luu HH, Kang Q, Kummer JL, Deng ZL, Olson K, Primus F, Montag AG, He TC, Haydon RC, Toolan BC: BMP-14 gene therapy increases tendon tensile strength in a rat model of Achilles tendon injury. J Bone Joint Surg Am Vol 2007, 89(6):1315-1320.
- [8]Lieberman JR, Daluiski A, Einhorn TA: The role of growth factors in the repair of bone. Biology and clinical applications. J Bone Joint Surg Am Vol 2002, 84-A(6):1032-1044.
- [9]Murray DH, Kubiak EN, Jazrawi LM, Araghi A, Kummer F, Loebenberg MI, Zuckerman JD: The effect of cartilage-derived morphogenetic protein 2 on initial healing of a rotator cuff defect in a rat model. J Shoulder Elbow Surg/Am Shoulder Elbow Surg 2007, 16(2):251-254.
- [10]Rodeo SA, Potter HG, Kawamura S, Turner AS, Kim HJ, Atkinson BL: Biologic augmentation of rotator cuff tendon-healing with use of a mixture of osteoinductive growth factors. J Bone Joint Surg Am Vol 2007, 89(11):2485-2497.
- [11]Cheung EV, Silverio L, Sperling JW: Strategies in biologic augmentation of rotator cuff repair: a review. Clinical Orthopaedics Relat Res 2010, 468(6):1476-1484.
- [12]Angeline ME, Rodeo SA: Biologics in the management of rotator cuff surgery. Clinics Sports Med 2012, 31(4):645-663.
- [13]Kovacevic D, Rodeo SA: Biological augmentation of rotator cuff tendon repair. Clinical Orthopaedics Relat Res 2008, 466(3):622-633.
- [14]Katakam M, Banga AK: Use of poloxamer polymers to stabilize recombinant human growth hormone against various processing stresses. Pharma Dev Technol 1997, 2(2):143-149.
- [15]Dumortier G, Grossiord JL, Agnely F, Chaumeil JC: A review of Poloxamer 407 pharmaceutical and pharmacological characteristics. Pharma Res 2006, 23(12):2709-2728.
- [16]Veyries ML, Couarraze G, Geiger S, Agnely F, Massias L, Kunzli B, Faurisson F, Rouveix B: Controlled release of vancomycin from Poloxamer 407 gels. Int J Pharma 1999, 192(2):183-193.
- [17]Manchio JV, Litchfield CR, Zeheb R, Bryan DJ: Evaluation of a novel reverse thermosensitive polymer for use in microvascular surgery. J Reconstruc Microsurg 2009, 25(1):69-76.
- [18]Yu CH, Lee JH, Baek HR, Nam H: The effectiveness of Poloxamer 407-based new anti-adhesive material in a laminectomy model in rats. Eur Spine J 2012, 21(5):971-979.
- [19]Gimbel JA, Van Kleunen JP, Mehta S, Perry SM, Williams GR, Soslowsky LJ: Supraspinatus tendon organizational and mechanical properties in a chronic rotator cuff tear animal model. J Biomech 2004, 37(5):739-749.
- [20]Rich L, Whittaker P: Collagen and picrosirius red staining: a polarized light assessment of fibrillar hue and spatial distribution. Braz J Morphol Sci 2005, 22(2):97-104.
- [21]Ide J, Kikukawa K, Hirose J, Iyama K, Sakamoto H, Fujimoto T, Mizuta H: The effect of a local application of fibroblast growth factor-2 on tendon-to-bone remodeling in rats with acute injury and repair of the supraspinatus tendon. J Shoulder Elbow Surg/Am Shoulder Elbow Surg 2009, 18(3):391-398.
- [22]Galatz LM, Silva MJ, Rothermich SY, Zaegel MA, Havlioglu N, Thomopoulos S: Nicotine delays tendon-to-bone healing in a rat shoulder model. J Bone Joint Surg Am Vol 2006, 88(9):2027-2034.
- [23]Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL: Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg/Am Shoulder Elbow Surg 2006, 15(3):290-299.
- [24]Harryman DT 2nd, Mack LA, Wang KY, Jackins SE, Richardson ML, Matsen FA 3rd: Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff. J Bone Joint Surg Am Vol 1991, 73(7):982-989.
- [25]Iannotti JP, Deutsch A, Green A, Rudicel S, Christensen J, Marraffino S, Rodeo S: Time to failure after rotator cuff repair: a prospective imaging study. J Bone Joint Surg Am Vol 2013, 95(11):965-971.
- [26]McCarron JA, Derwin KA, Bey MJ, Polster JM, Schils JP, Ricchetti ET, Iannotti JP: Failure with continuity in rotator cuff repair “healing”. Am J Sports Med 2013, 41(1):134-141.
- [27]Sonnabend DH, Howlett CR, Young AA: Histological evaluation of repair of the rotator cuff in a primate model. J Bone Joint Surg British Vol 2010, 92(4):586-594.
- [28]Soslowsky LJ, Carpenter JE, DeBano CM, Banerji I, Moalli MR: Development and use of an animal model for investigations on rotator cuff disease. J Shoulder Elbow Surg/Am Shoulder Elbow Surg 1996, 5(5):383-392.