| Journal of Orthopaedic Surgery and Research | |
| Assessment of retention force and bone apposition in two differently coated femoral stems after 6 months of loading in a goat model | |
| Kjetil Søreide3  Kari Indrekvam4  Einar Sudmann2  Nils R Gjerdet1  Knut Harboe2  | |
| [1] Biomaterials, Department of Clinical Dentistry, University of Bergen, Bergen, Norway;Department of Clinical Medicine, University of Bergen, Bergen, Norway;Department of Gastrointestinal Surgery, Stavanger University Hospital, Stavanger, Norway;Kysthospitalet in Hagevik, Clinic of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway | |
| 关键词: Implant stability; Hip replacement; Loaded animal model; Calcium phosphate; Hydroxyapatite; | |
| Others : 1152194 DOI : 10.1186/s13018-014-0069-4 |
|
| received in 2014-03-06, accepted in 2014-07-18, 发布年份 2014 | |
PDF
|
|
【 摘 要 】
Background
Since the introduction of uncemented hip implants, there has been a search for the best surface coating to enhance bone apposition in order to improve retention. The surface coating of the different stems varies between products. The aim was to assess the retention force and bone adaption in two differently coated stems in a weight-bearing goat model.
Materials and methods
Hydroxyapatite (HA) and electrochemically deposited calcium phosphate (CP; Bonit®) on geometrically comparable titanium-based femoral stems were implanted into 12 (CP group) and 35 (HA group) goats. The animal model included physiological loading of the implants for 6 months. The pull-out force of the stems was measured, and bone apposition was microscopically evaluated.
Results
After exclusion criteria were applied, the number of available goats was 4 in the CP group and 11 in the HA group. The CP-coated stems had significantly lower retention forces compared with the HA-coated ones after 6 months (CP median 47 N, HA median 1,696 N, p = 0.003). Bone sections revealed a lower degree of bone apposition in the CP-coated stems, with more connective tissue in the bone/implant interface compared with the HA group.
Conclusion
In this study, HA had better bone apposition and needed greater pull-out force in loaded implants. The application of CP on the loaded titanium surface to enhance the apposition of bone is questioned.
【 授权许可】
2014 Harboe et al.; licensee BioMed Central Ltd.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20150406143950524.pdf | 2009KB | ||
| Figure 4. | 130KB | Image | |
| Figure 3. | 16KB | Image | |
| Figure 2. | 54KB | Image | |
| Figure 1. | 25KB | Image |
【 图 表 】
Figure 1.
Figure 2.
Figure 3.
Figure 4.
【 参考文献 】
- [1]Furnes O, Havelin L, Espehaug B, Steindal K, Sørås T: The Norwegian Arthroplasty Register - Annual Report. Norway, Bergen; 2012.
- [2]Azegami S, Gurusamy KS, Parker MJ: Cemented versus uncemented hemiarthroplasty for hip fractures: a systematic review of randomised controlled trials. Hip Int 2011, 21:509-517.
- [3]Gjertsen JE, Lie SA, Vinje T, Engesaeter LB, Hallan G, Matre K, Furnes O: More re-operations after uncemented than cemented hemiarthroplasty used in the treatment of displaced fractures of the femoral neck: an observational study of 11,116 hemiarthroplasties from a national register. J Bone Joint Surg Br 2012, 94:1113-1119.
- [4]McMinn DJ, Snell KI, Daniel J, Treacy RB, Pynsent PB, Riley RD: Mortality and implant revision rates of hip arthroplasty in patients with osteoarthritis: registry based cohort study. BMJ 2012, 344:e3319.
- [5]Dale H, Fenstad AM, Hallan G, Havelin LI, Furnes O, Overgaard S, Pedersen AB, Karrholm J, Garellick G, Pulkkinen P, Eskelinen A, Makela K, Engesaeter LB: Increasing risk of prosthetic joint infection after total hip arthroplasty. Acta Orthop 2012, 83:449-458.
- [6]Brennan SA, Khan F, Kiernan C, Queally JM, McQuillan J, Gormley IC, O'Byrne JM: Dislocation of primary total hip arthroplasty and the risk of redislocation. Hip Int 2012, 22:500-504.
- [7]Schmalzried TP: The painful hip: diagnosis and deliverance. J Bone Joint Surg Br 2012, 94-B:55-57.
- [8]Reimeringer M, Nuno N, Desmarais-Trepanier C, Lavigne M, Vendittoli PA: The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis. Comput Methods Biomech Biomed Engin 2013, 16:1221-1231.
- [9]Capello WN, D'Antonio JA, Feinberg JR, Manley MT: Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old. A concise follow-up of a previous report. J Bone Joint Surg Am 2003, 85-A:885-889.
- [10]Hennessy DW, Callaghan JJ, Liu SS: Second-generation extensively porous-coated THA stems at minimum 10-year followup. Clin Orthop Relat Res 2009, 467:2290-2296.
- [11]Boe BG, Rohrl SM, Heier T, Snorrason F, Nordsletten L: A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems. Acta Orthop 2011, 82:13-19.
- [12]Harboe K, Enoksen CH, Gjerdet NR, Sudmann E: Development of a femoral stem providing strong anchorage and facilitated removal. An experimental study in goats. Vet Comp Orthop Traumatol 2012, 25:95-101.
- [13]Peters A: Postoperatieve fixatiewagen voor grote dieren. Biotechniek 1990, 1990:79-80.
- [14]An YH, Draughn RA: Mechanical Testing of Bone and the Bone-Implant Interface. CRC, South Carolina; 2000.
- [15]Geesink RG, De Groot K, Klein CP: Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop Relat Res 1987, 225:147-170.
- [16]Reigstad O, Franke-Stenport V, Johansson CB, Wennerberg A, Rokkum M, Reigstad A: Improved bone ingrowth and fixation with a thin calcium phosphate coating intended for complete resorption. J Biomed Mater Res B Appl Biomater 2007, 83:9-15.
- [17]Røkkum M, Reigstad A, Johansson CB: HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2–8 years after implantation. Acta Orthop Scand 2002, 73:298-306.
- [18]Bastian L, Hufner T, Mossinger E, Geerling J, Goesling T, Busche M, Kendoff D, Bading S, Rosenthal H, Krettek C: Integration of modern technologies in therapy of sarcomas of the pelvis. Computer-assisted hemipelvectomy and implantation of a “custom-made” Bonit gentamycin coated partial pelvic prosthesis. Unfallchirurg 2003, 106:956-962.
- [19][http:/ / www.dot-coating.de/ fileadmin/ dot/ Dokumente/ english/ DOTimplantSOURCE/ F-BONIT-270608-EN-klein.pdf] webcite Accelerated healing through the use of electrochemically deposited CaP BONIT® coatings..
- [20]Reigstad O, Johansson C, Stenport V, Wennerberg A, Reigstad A, Rokkum M: Different patterns of bone fixation with hydroxyapatite and resorbable CaP coatings in the rabbit tibia at 6, 12, and 52 weeks. J Biomed Mater Res B Appl Biomater 2011, 99:14-20.
- [21]Becker P, Neumann HG, Nebe B, Luthen F, Rychly J: Cellular investigations on electrochemically deposited calcium phosphate composites. J Mater Sci Mater Med 2004, 15:437-440.
- [22]Buratti CA, D'Arrigo C, Guido G, Lenzi F, Logroscino GD, Magliocchetti G, Mannocci C, Patella S, Patella V, Salvi V, Speranza A, Speciale D, Spinarelli A, Topa D: Assessment of the initial stability of the Symax femoral stem with EBRA-FCA: a multicentric study of 85 cases. Hip Int 2009, 19:24-29.
- [23]ten Broeke RH, Alves A, Baumann A, Arts JJ, Geesink RG: Bone reaction to a biomimetic third-generation hydroxyapatite coating and new surface treatment for the Symax hip stem. J Bone Joint Surg Br 2011, 93:760-768.
- [24]ten Broeke RH, Hendrickx RP, Leffers P, Jutten LM, Geesink RG: Randomised trial comparing bone remodelling around two uncemented stems using modified Gruen zones. Hip Int 2012, 22:41-49.
- [25]Morscher EW, Hefti A, Aebi U: Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br 1998, 80:267-272.
- [26]Wang J, Sun C, Wang Y: Early bone apposition and 1-year performance of the electrodeposited calcium phosphate coatings: an experimental study in rabbit femora. Clin Oral Implants Res 2010, 21:951-960.
- [27]Soballe K, Hansen ES, B-Rasmussen H, Jorgensen PH, Bunger C: Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 1992, 10:285-299.
- [28]Stephenson PK, Freeman MA, Revell PA, Germain J, Tuke M, Pirie CJ: The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant. J Arthroplasty 1991, 6:51-58.
- [29]Klenke FM, Liu Y, Yuan H, Hunziker EB, Siebenrock KA, Hofstetter W: Impact of pore size on the vascularization and osseointegration of ceramic bone substitutes in vivo. J Biomed Mater Res A 2008, 85:777-786.
- [30]Yamamoto M, Tabata Y, Kawasaki H, Ikada Y: Promotion of fibrovascular tissue ingrowth into porous sponges by basic fibroblast growth factor. J Mater Sci Mater Med 2000, 11:213-218.
PDF