期刊论文详细信息
BMC Medical Imaging
Improved R2* liver iron concentration assessment using a novel fuzzy c-mean clustering scheme
Rungroj Krittayaphong2  Vip Viprakasit1  Pairash Saiviroonporn3 
[1] Haematology/Oncology Division, Department of Pediatrics and Thalassemia Center, Mahidol University, Bangkok, Thailand;Division of Cardiology, Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand;Division of Diagnostic Radiology, Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
关键词: Thalassemia;    Liver segmentation;    Liver R2* measurement;    Liver iron overload;    FCM;   
Others  :  1233372
DOI  :  10.1186/s12880-015-0097-5
 received in 2015-04-16, accepted in 2015-10-29,  发布年份 2015
PDF
【 摘 要 】

Background

In thalassemia patients, R2* liver iron concentration (LIC) measurement is a common clinical tool for assessing iron overload and for determining necessary chelator dose and evaluating its efficacy. Despite the importance of accurate LIC measurement, existing methods suffer from LIC variability, especially at the severe iron overload range due to inclusion of vessel parts in LIC calculation. In this study, we build upon previous Fuzzy C-Mean (FCM) clustering work to formulate a scheme with superior performance in segmenting vessel pixels from the parenchyma. Our method (MIX-FCM) combines our novel 2D-FCM with the existing 1D-FCM algorithm. This study further assessed possible optimal clustering parameters (OP scheme) and proposed a semi-automatic (SA) scheme for routine clinical application.

Methods

Segmentation of liver parenchyma and vessels was performed on T2* images and their LIC maps in 196 studies from 147 thalassemia major patients. We used manual segmentation as the reference. 1D-FCM clustering was performed on the acquired image alone and 2D-FCM used both the acquired image and its LIC data. To execute the MIX-FCM method, the best outcome (OP-MIX-FCM) was selected from the aforementioned methods and was compared to the SA-MIX-FCM scheme. We used the percent value of the normalized interquartile range (nIQR) to its median to evaluate the variability of all methods.

Results

2D-FCM clustering is more effective than 1D-FCM clustering at the severe overload range only, but inferior for other ranges (where 1D-FCM provides suitable results). This complementary performance between the two methods allows MIX-FCM to improve results for all ranges. OP-MIX-FCM clustering error was 2.1 ± 2.3 %, compared with 10.3 ± 9.9 % and 7.0 ± 11.9 % from 1D- and 2D-FCM clustering, respectively. SA-MIX-FCM result was comparable to OP-MIX-FCM result, with both schemes showing ability to decrease overall nIQR by approximately 30 %.

Conclusion

Our proposed 2D-FCM algorithm is not as superior to 1D-FCM as hypothesized. In contrast, our MIX-FCM method benefits from the best of both methods to obtain the highest segmentation accuracy at all ranges. Moreover, segmentation accuracy of the practical scheme (SA-MIX-FCM) is comparable to segmentation accuracy of the reference scheme (OP-MIX-FCM). Finally, we confirmed that segmentation is crucial to improving LIC assessments, especially at the severe iron overload range.

【 授权许可】

   
2015 Saiviroonporn et al.

【 预 览 】
附件列表
Files Size Format View
20151120022458251.pdf 2277KB PDF download
Fig. 7. 106KB Image download
Fig. 6. 99KB Image download
Fig. 5. 90KB Image download
Fig. 4. 90KB Image download
Fig. 3. 81KB Image download
Fig. 2. 84KB Image download
Fig. 1. 54KB Image download
【 图 表 】

Fig. 1.

Fig. 2.

Fig. 3.

Fig. 4.

Fig. 5.

Fig. 6.

Fig. 7.

【 参考文献 】
  • [1]Cohen AR, Galanello R, Pennell DJ, Cunningham MJ, Vichinsky E. Thalassemia. Hematology Am Soc Hematol Educ Program. 2004:14–34.
  • [2]Rund D, Rachmilewitz E. Beta-thalassemia. N Engl J Med. 2005; 353(11):1135-46.
  • [3]Anderson LJ. Assessment of iron overload with T2* magnetic resonance imaging. Prog Cardiovasc Dis. 2011; 54(3):287-94.
  • [4]Taher AT, Musallam KM, Wood JC, Cappellini MD. Magnetic resonance evaluation of hepatic and myocardial iron deposition in transfusion-independent thalassemia intermedia compared to regularly transfused thalassemia major patients. Am J Hematol. 2010; 85(4):288-90.
  • [5]Wood JC, Ghugre N. Magnetic resonance imaging assessment of excess iron in thalassemia, sickle cell disease and other iron overload diseases. Hemoglobin. 2008; 32(1–2):85-96.
  • [6]Angelucci E, Barosi G, Camaschella C, Cappellini MD, Cazzola M, Galanello R et al.. Italian Society of Hematology practice guidelines for the management of iron overload in thalassemia major and related disorders. Haematologica. 2008; 93(5):741-52.
  • [7]Anderson LJ, Holden S, Davis B, Prescott E, Charrier CC, Bunce NH et al.. Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J. 2001; 22(23):2171-9.
  • [8]St Pierre TG, Clark PR, Chua-Anusorn W. Measurement and mapping of liver iron concentrations using magnetic resonance imaging. Ann N Y Acad Sci. 2005; 1054:379-85.
  • [9]Wood JC, Enriquez C, Ghugre N, Tyzka JM, Carson S, Nelson MD et al.. MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion- dependent thalassemia and sickle cell disease patients. Blood. 2005; 106(4):1460-5.
  • [10]Meloni A, Rienhoff HY, Jones A, Pepe A, Lombardi M, Wood JC. The use of appropriate calibration curves corrects for systematic differences in liver R2* values measured using different software packages. Br J Haematol. 2013; 161(6):888-91.
  • [11]Carpenter JP, Pennell DJ. Role of T2* magnetic resonance in monitoring iron chelation therapy. Acta Haematol. 2009; 122(2–3):146-54.
  • [12]Cohen AR. New advances in iron chelation therapy. Hematology Am Soc Hematol Educ Program. 2006:42–7.
  • [13]Kontoghiorghes GJ. A new era in iron chelation therapy: the design of optimal, individually adjusted iron chelation therapies for the complete removal of iron overload in thalassemia and other chronically transfused patients. Hemoglobin. 2009; 33(5):332-8.
  • [14]Noetzli LJ, Carson SM, Nord AS, Coates TD, Wood JC. Longitudinal analysis of heart and liver iron in thalassemia major. Blood. 2008; 112(7):2973-8.
  • [15]Saiviroonporn P, Viprakasit V, Sanpakit K, Wood JC, Krittayaphong R. Intersite validations of the pixel-wise method for liver R2* analysis in transfusion-dependent thalassemia patients: a more accessible and affordable diagnostic technology. Hematol Oncol Stem Cell Ther. 2012; 5(2):91-5.
  • [16]Saiviroonporn P, Viprakasit V, Maneesai A, Siritanaratkul N, Pongtanakul B, Wood JC et al.. Inter-site validations of the Pixel-Wise method for cardiac T2* analysis in transfusion-dependent Thai thalassemia patients. J Med Assoc Thai. 2012; 95 Suppl 2:S165-72.
  • [17]Positano V, Salani B, Pepe A, Santarelli MF, De Marchi D, Ramazzotti A et al.. Improved T2* assessment in liver iron overload by magnetic resonance imaging. Magn Reson Imaging. 2009; 27(2):188-97.
  • [18]Ghugre NR, Enriquez CM, Coates TD, Nelson MD, Wood JC. Improved R2* measurements in myocardial iron overload. J Magn Reson Imaging. 2006; 23(1):9-16.
  • [19]Deng J, Rigsby CK, Schoeneman S, Boylan E. A semiautomatic postprocessing of liver R2* measurement for assessment of liver iron overload. Magn Reson Imaging. 2012; 30(6):799-806.
  • [20]McCarville MB, Hillenbrand CM, Loeffler RB, Smeltzer MP, Song R, Li CS et al.. Comparison of whole liver and small region-of-interest measurements of MRI liver R2* in children with iron overload. Pediatr Radiol. 2010; 40(8):1360-7.
  • [21]Palmieri F, di Salvo G, Perrotta S, Ragozzino A. Re: Improved T2* assessment in liver iron overload by magnetic resonance imaging. Magn Reson Imaging. 2010; 28(2):301-3.
  • [22]Positano V, Salani B, Scattini B, Santarelli MF, Ramazzotti A, Pepe A et al.. A robust method for assessment of iron overload in liver by magnetic resonance imaging. Conf Proc IEEE Eng Med Biol Soc. 2007; 2007:2895-8.
  • [23]Bezdek JC, Hall LO, Clarke LP. Review of MR image segmentation techniques using pattern recognition. Med Phys. 1993; 20(4):1033-48.
  • [24]Eggert LD, Sommer J, Jansen A, Kircher T, Konrad C. Accuracy and reliability of automated gray matter segmentation pathways on real and simulated structural magnetic resonance images of the human brain. PLoS One. 2012; 7(9):e45081.
  • [25]Hsieh TM, Liu YM, Liao CC, Xiao F, Chiang IJ, Wong JM. Automatic segmentation of meningioma from non-contrasted brain MRI integrating fuzzy clustering and region growing. BMC Med Inform Decis Mak. 2011; 11:54. BioMed Central Full Text
  • [26]Wang Z, Song Q, Soh YC, Sim K. An adaptive spatial information-theoretic fuzzy clustering algorithm for image segmentation. Comput Vis Image Understanding. 2013; 117:1412-20.
  • [27]Pham DL, Prince JL. Adaptive fuzzy segmentation of magnetic resonance images. IEEE Trans Med Imag. 1999; 18(9):737-52.
  • [28]Ahmed MN, Yamany SM, Mohamed N, Farag AA, Moriarty T. A modified Fuzzy C- Mean algorithm for bias field estimation and segmentation of MRI data. IEEE Trans Med Imag. 2002; 21(3):993-9.
  • [29]Liew AW, Yan H. An adaptive spatial fuzzy clustering algorithm for 3-D MR image segmentation. IEEE Trans Med Imag. 2003; 22(9):1063-75.
  • [30]Taher AT, Musallam KM, Inati A. Iron overload: consequences, assessment, and monitoring. Hemoglobin. 2009; 33 Suppl 1:S46-57.
  • [31]Brewer CJ, Coates TD, Wood JC. Spleen R2 and R2* in iron-overloaded patients with sickle cell disease and thalassemia major. J Magn Reson Imaging. 2009; 29(2):357-64.
  文献评价指标  
  下载次数:46次 浏览次数:7次