期刊论文详细信息
BMC Medical Research Methodology
Challenges in standardization of blood pressure measurement at the population level
Kari Kuulasmaa1  Tarja Palosaari1  Grazyna Broda2  Satu Männistö1  Androniki Naska3  Päivikki Koponen1  Hanna Tolonen1 
[1]Department of Health, National Institute for Health and Welfare, Helsinki, Finland
[2]The Cardinal Stefan Wyszynski Institute of Cardiology, Warsaw, Poland
[3]Hellenic Health Foundation, Athens, Greece and Department of Hygiene, Epidemiology and Medical Statistics, University of Athens Medical School, Athens, Greece
关键词: Methodology;    Surveillance;    Blood pressure;   
Others  :  1177558
DOI  :  10.1186/s12874-015-0020-3
 received in 2013-11-20, accepted in 2015-03-18,  发布年份 2015
PDF
【 摘 要 】

Background

Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed.

Methods

The European Health Examination Survey (EHES) Pilot project was conducted in 2009–2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization.

Results

The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement.

Conclusions

It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

【 授权许可】

   
2015 Tolonen et al.; licensee BioMed Central.

【 预 览 】
附件列表
Files Size Format View
20150502023049335.pdf 416KB PDF download
【 参考文献 】
  • [1]Rose GA, Khaw K-T, Marmot MG: Rose’s strategy of preventive medicine: the complete original text. New edition. Oxford University Press, Oxford; New York; 2008.
  • [2]Kawahara J, Sano H, Fukuzaki H, Saito K, Hirouchi H: Acute effects of exposure to cold on blood pressure, platelet function and sympathetic nervous activity in humans. Am J Hypertens 1989, 2(9):724-726.
  • [3]Campbell NR, McKay DW, Chockalingam A, Fodor JG: Errors in assessment of blood pressure: patient factors. Can J Public Health 1994, 85(Suppl 2):S12-S17.
  • [4]Handler J: The importance of accurate blood pressure measurement. Perm J 2009, 13(3):51-54.
  • [5]Campbell NR, McKay DW: Accurate blood pressure measurement: why does it matter? CMAJ 1999, 161(3):277-278.
  • [6]Gould BA, Hornung RS, Kieso HA, Altman DG, Raftery EB: Is the blood pressure the same in both arms? Clin Cardiol 1985, 8(8):423-426.
  • [7]Jamieson MJ, Webster J, Philips S, Jeffers TA, Scott AK, Robb OJ, et al.: The measurement of blood pressure: sitting or supine, once or twice? J Hypertens 1990, 8(7):635-640.
  • [8]Keele-Smith R, Price-Daniel C: Effects of crossing legs on blood pressure measurement. Clin Nurs Res 2001, 10(2):202-213.
  • [9]Netea RT, Lenders JW, Smits P, Thien T: Arm position is important for blood pressure measurement. J Hum Hypertens 1999, 13(2):105-109.
  • [10]Netea RT, Smits P, Lenders JW, Thien T: Does it matter whether blood pressure measurements are taken with subjects sitting or supine? J Hypertens 1998, 16(3):263-268.
  • [11]O’Brien E, Asmar R, Beilin L, Imai Y, Mallion JM, Mancia G, et al.: European society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens 2003, 21(5):821-848.
  • [12]Schulze MB, Kroke A, Saracci R, Boeing H: The effect of differences in measurement procedure on the comparability of blood pressure estimates in multi-centre studies. Blood Press Monit 2002, 7(2):95-104.
  • [13]O’Brien E, Petrie J, Little W, de Swiet M, Padfield P: The British hypertension society protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993, 11(Suppl 2):S43-S62.
  • [14]O’Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al.: European society of hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit 2010, 15(1):23-38.
  • [15]Association for the Advancement of Medical Instrumentation. Non-invasive sphygmomanometers - part 2: clinical validation of automated measurement type. ANSI/AAMI/ISO 81060–2. Association for the Advancement of Medical Instrumentatio, 2013.
  • [16]Mauro AMP: Effects of bell versus diaphragm on indirect blood-pressure measurement. Heart Lung 1988, 17(5):489-494.
  • [17]Kantola I, Vesalainen R, Kangassalo K, Kariluoto A: Bell or diaphragm in the measurement of blood pressure? J Hypertens 2005, 23(3):499-503.
  • [18]Coleman AJ, Steel SD, Ashworth M, Vowler SL, Shennan A: Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care. Blood Press Monit 2005, 10(4):181-188.
  • [19]de Greeff A, Lorde I, Wilton A, Seed P, Coleman AJ, Shennan AH: Calibration accuracy of hospital-based non-invasive blood pressure measuring devices. J Hum Hypertens 2010, 24(1):58-63.
  • [20]Rose G: Standardisation of observers in blood-pressure measurement. Lancet 1965, 1(7387):673-674.
  • [21]Beevers G, Lip GY, O’Brien E: ABC of hypertension: blood pressure measurement. Part II-conventional sphygmomanometry: technique of auscultatory blood pressure measurement. BMJ 2001, 322(7293):1043-1047.
  • [22]de Lusignan S, Belsey J, Hague N, Dzregah B: End-digit preference in blood pressure recordings of patients with ischaemic heart disease in primary care. J Hum Hypertens 2004, 18(4):261-265.
  • [23]Hessel PA: Terminal digit preference in blood pressure measurements: effects on epidemiological associations. Int J Epidemiol 1986, 15(1):122-125.
  • [24]Neufeld PD, Johnson DL: Observer error in blood pressure measurement. CMAJ 1986, 135(6):633-637.
  • [25]Turner MJ, Baker AB, Kam PC: Effects of systematic errors in blood pressure measurements on the diagnosis of hypertension. Blood Press Monit 2004, 9(5):249-253.
  • [26]Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al.: Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Hypertension 2005, 45(1):142-161.
  • [27]WHO MONICA Project. MONICA manual, part III: population survey, section 1: population survey data component. Volume 2012. 1997. Available at URL:http://www.thl.fi/publications/monica/manual/part3/iii-1.htm, URN:NBN:fi-fe19981131
  • [28]Luepker RV, Evans A, McKeigue P, Srinath Reddy K: Cardiovascular survey methods. 3rd edition. World Health Organization, Geneva; 2004.
  • [29]Tolonen H, Koponen P: 5.1 Blood pressure in Tolonen H. (Ed.) EHES manual, part B. Fieldwork procedures. In EHES manual, part B fieldwork procedures. Edited by Tolonen H. National Institute for Health and Welfare, Helsinki; 2013.
  • [30]Kuulasmaa K, Tolonen H, Koponen P, Kilpelainen K, Avdicova M, Broda G, et al.: An overview of the European health examination survey pilot joint action. Arch Public Health 2012, 70(1):20. BioMed Central Full Text
  • [31]Tolonen H: EHES manual. Part A. Planning and preparing for the survey. Volume directions 2013_001. National Institute for Health and Welfare, Helsinki; 2013.
  • [32]Tolonen H: EHES manual. Part B. Fieldwork procedures. Volume directions 2013_002. National Institute for Health and Welfare, Helsinki; 2013.
  • [33]Training materials. [http://www.ehes.info/training_materials/index.htm]
  • [34]Ataman SL, Cooper R, Rotimi C, McGee D, Osotimehin B, Kadiri S, et al.: Standardization of blood pressure measurement in an international comparative study. J Clin Epidemiol 1996, 49(8):869-877.
  • [35]Ostchega Y, Prineas RJ, Paulose-Ram R, Grim CM, Willard G, Collins D: National health and nutrition examination survey 1999–2000: effect of observer training and protocol standardization on reducing blood pressure measurement error. J Clin Epidemiol 2003, 56(8):768-774.
  • [36]Hense HW, Koivisto AM, Kuulasmaa K, Zaborskis A, Kupsc W, Tuomilehto J: Assessment of blood pressure measurement quality in the baseline surveys of the WHO MONICA project. J Hum Hypertens 1995, 9(12):935-946.
  • [37]O’Brien E, Mee F, Tan KS, Atkins N, Omalley K: Training and assessment of observers for blood-pressure measurement in hypertension research. J Hum Hypertens 1991, 5(1):7-10.
  • [38]European Commission. Commission Regulation (EU) No 847/2012 on 19 September 2012 amending Annex XVII to Regulation (EC) No 1907/2006 of the European Parliament and of the council on the registration, evaluation, authorisation and restriction of chemicals (REACH) as regards mercury. In 847/2012. Edited by European Commission. Off J Eur Union, L253, 20.9.2012.
  • [39]Ostchega Y, Zhang G, Sorlie P, Hughes JP, Reed-Gillette DS, Nwankwo T, et al. Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: national health and nutrition examination survey, 2009–2010. Natl Health Stat Report. 2012: (59):1–15.
  • [40]Pruijm MT, Wuerzner G, Glatz N, Alwan H, Ponte B, Ackermann D, et al.: A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol. Blood Press Monit 2010, 15(6):322-325.
  • [41]Stergiou GS, Karpettas N, Kollias A, Destounis A, Tzamouranis D: A perfect replacement for the mercury sphygmomanometer: the case of the hybrid blood pressure monitor. J Hum Hypertens 2012, 26(4):220-227.
  • [42]Frohlich ED, Grim CM, Labarthe DR, Maxwell MH, Perloff D, Weidman WH: Recommendations for human blood pressure determination by sphygmomanometers. Report of a special task force appointed by the steering committee, American Heart Association. Hypertension 1988, 11(2):209A-222A.
  • [43]Fornells JM, Borras JM, Balaguer-Vintro I: The preference for the final digits in blood pressure determination: a continuing education experience. Aten Primaria 1990, 7(2):102-105.
  • [44]Kolb C, Huss R, Mengden T, Vetter W: How reliable is conventional blood pressure registration? Comparison with a semi-automatic device. Schweiz Rundsch Med Prax 1991, 80(12):286-290.
  • [45]Tolonen H, Kuulasmaa K, Laatikainen T, Wolf H: the European Health Risk Monitoring Project: Recommendations for indicators, international collaboration, protocol and manual of operations for chronic disease risk factor surveys. Finnish National Public Health Institute, Helsinki; 2002.
  文献评价指标  
  下载次数:12次 浏览次数:51次