BioMedical Engineering OnLine | |
Quantification of functional hand grip using electromyography and inertial sensor-derived accelerations: clinical implications | |
Jaime Martin-Martin1  Antonio I Cuesta-Vargas2  | |
[1] Departamento de Psiquiatría y Fisioterapia, Facultad de Ciencias de la Salud, Universidad de Malaga, Andalucia Tech, Instituto de Biomedicina de Malaga (IBIMA), Grupo de Clinimetria (AE-14), Malaga, Spain | |
[2] School of Clinical Science, Faculty of Health Science, Queensland University Technology, Brisbane, Australia | |
关键词: Functions; Electromyography; Signal; Kinematic; Assessment; | |
Others : 1084187 DOI : 10.1186/1475-925X-13-161 |
|
received in 2014-09-01, accepted in 2014-12-04, 发布年份 2014 | |
【 摘 要 】
Background
Assessing hand injury is of great interest given the level of involvement of the hand with the environment. Knowing different assessment systems and their limitations generates new perspectives. The integration of digital systems (accelerometry and electromyography) as a tool to supplement functional assessment allows the clinician to know more about the motor component and its relation to movement. Therefore, the purpose of this study was the kinematic and electromyography analysis during functional hand movements.
Method
Ten subjects carried out six functional movements (terminal pinch, termino-lateral pinch, tripod pinch, power grip, extension grip and ball grip). Muscle activity (hand and forearm) was measured in real time using electromyograms, acquired with the Mega ME 6000, whilst acceleration was measured using the AcceleGlove.
Results
Electrical activity and acceleration variables were recorded simultaneously during the carrying out of the functional movements. The acceleration outcome variables were the modular vectors of each finger of the hand and the palm. In the electromyography, the main variables were normalized by the mean and by the maximum muscle activity of the thenar region, hypothenar, first interosseous dorsal, wrist flexors, carpal flexors and wrist extensors.
Conclusions
Knowing muscle behavior allows the clinician to take a more direct approach in the treatment. Based on the results, the tripod grip shows greater kinetic activity and the middle finger is the most relevant in this regard. Ball grip involves most muscle activity, with the thenar region playing a fundamental role in hand activity.
Clinical relevance
Relating muscle activation, movements, individual load and displacement offers the possibility to proceed with rehabilitation by individual component.
【 授权许可】
2014 Martin-Martin and Cuesta-Vargas; licensee BioMed Central Ltd.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
20150113155320755.pdf | 857KB | download | |
Figure 2. | 74KB | Image | download |
Figure 1. | 57KB | Image | download |
【 图 表 】
Figure 1.
Figure 2.
【 参考文献 】
- [1]Young RW: Evolution of the human hand: the role of throwing and clubbing. J Anat 2003, 202:165-174.
- [2]Hill EL, Khanem F: The development of hand preference in children: the effect of task demands and links with manual dexterity. Brain Cogn 2009, 71:99-107.
- [3]Rosberg H-E, Carlsson KS, Cederlund RI, Ramel E, Dahlin LB: Costs and outcome for serious hand and arm injuries during the first year after trauma - a prospective study. BMC Public Health 2013, 13:501. BioMed Central Full Text
- [4]Shelton FD, Volpe BT, Reding M: Motor impairment as a predictor of functional recovery and guide to rehabilitation treatment after stroke. Neurorehabil Neural Repair 2001, 15:229-237.
- [5]Light CM, Chappell PH, Kyberd PJ: Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: normative data, reliability, and validity. Arch Phys Med Rehabil 2002, 83:776-783.
- [6]Drost G, Stegeman DF, van Engelen BGM, Zwarts MJ: Clinical applications of high-density surface EMG: a systematic review. J Electromyogr Kinesiol 2006, 16:586-602.
- [7]Merletti R, Aventaggiato M, Botter A, Holobar A, Marateb H, Vieira TMM: Advances in surface EMG: recent progress in detection and processing techniques. Crit Rev Biomed Eng 2010, 38:305-345.
- [8]Muceli S, Jiang N, Farina D: Multichannel surface EMG based estimation of bilateral hand kinematics during movements at multiple degrees of freedom. Conf Proc Annu Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Conf 2010, 2010:6066-6069.
- [9]Hashemi Oskouei A, Paulin MG, Carman AB: Intra-session and inter-day reliability of forearm surface EMG during varying hand grip forces. J Electromyogr Kinesiol 2012, 23(1):216-222.
- [10]Hoozemans MJM, van Dieën JH: Prediction of handgrip forces using surface EMG of forearm muscles. J Electromyogr Kinesiol Off J Int Soc Electrophysiol Kinesiol 2005, 15:358-366.
- [11]Takala E-P, Toivonen R: Placement of forearm surface EMG electrodes in the assessment of hand loading in manual tasks. Ergonomics 2013, 56:1159-1166.
- [12]Cuesta-Vargas A, Galán-Mercant A, Williams J: The use of inertial sensors system for human motion analysis. Phys Ther Rev 2010, 15:462-473.
- [13]Martin-Martin J, Cuesta-Vargas AI: A biomechanical study of spherical grip. SpringerPlus 2013, 2:591. BioMed Central Full Text
- [14]Martin-Martin J, Cuesta-Vargas AI: A kinematic and electromyographic study of grip force. Eur J Physiother 2014, 16:183-191.
- [15]Li Y, Chen X, Zhang X, Wang K, Wang Z: A sign-component-based framework for chinese sign language recognition using accelerometer and sEMG data. IEEE Trans Biomed Eng 2012, 59(10):2695-704.
- [16]WMA declaration of Helsinki - ethical principles for medical research involving human subjects. http://www.wma.net/es/30publications/10policies/b3/ webcite
- [17]Cuesta-Vargas AI, Gabel PC: Cross-cultural adaptation, reliability and validity of the Spanish version of the upper limb functional index. Health Qual Life Outcomes 2013, 11:126. BioMed Central Full Text
- [18]Hervás MT, Navarro Collado MJ, Peiró S, Rodrigo Pérez JL, López Matéu P, Martínez Tello I: Spanish version of the DASH questionnaire. Cross-cultural adaptation, reliability, validity and responsiveness. Med Clínica 2006, 127:441-447.
- [19]Patterson medical - strength dynamometer jamar hand. https://www.pattersonmedical.co.uk/app.aspx?cmd=get_item&id=1174 webcite
- [20]AcceleGlove. http://www.anthrotronix.com/ webcite
- [21]LLC B: Time measurement systems: Iso 8601, metric time, unix time, 12-hour clock, 24-hour clock, decimal time, thai six-hour clock. Memphis (Tennessee), USA: General Books LLC; 2010.
- [22]Mega Electronics Ltd pioneers in biosignal monitoring technology. http://www.megaemg.com/ webcite
- [23]Registration papers lessa - products. http://www.lessap.com/productos.php webcite
- [24]Perotto A, Delagi EF: Anatomical guide for the electromyographer: the limbs and trunk. Springfield: Charles C Thomas Publisher; 2005.
- [25]Hermens HJ, Freriks B, Merletti R: SENIAM: European Recommendations for Surface Electromyography. Volume 8. Enschede, the Netherlands: Roessingh Research and Development; 1999.
- [26]Merletti R: The electrode-skin interface and optimal detection of bioelectric signals. Physiol Meas 2010., 313 p preceding S157
- [27]PT JMM: Daniels and Worthingham’s muscle testing: techniques of manual examination, 8e (Daniel’s & Worthington’s Muscle Testing. 8th edition. California: Saunders; 2007.
- [28]IBM SPSS statistics. http://www-01.ibm.com/software/analytics/spss/products/statistics/ webcite
- [29]Gazzoni M, Celadon N, Mastrapasqua D, Paleari M, Margaria V, Ariano P: Quantifying forearm muscle activity during wrist and finger movements by means of multi-channel electromyography. PLoS One 2014, 9:e109943.
- [30]Ngeo JG, Tamei T, Shibata T: Continuous and simultaneous estimation of finger kinematics using inputs from an EMG-to-muscle activation model. J Neuroeng Rehabil 2014, 11:122. BioMed Central Full Text
- [31]Birdwell JA, Hargrove LJ, Weir RF, Kuiken TA: Extrinsic finger and thumb muscles command a virtual hand to allow individual finger and grasp control. IEEE Trans Biomed Eng 2014. Epub ahead of print
- [32]Danna-Dos Santos A, Poston B, Jesunathadas M, Bobich LR, Hamm TM, Santello M: Influence of fatigue on hand muscle coordination and EMG-EMG coherence during three-digit grasping. J Neurophysiol 2010, 104:3576-3587.
- [33]Qin J, Chen H, Dennerlein JT: Wrist posture affects hand and forearm muscle stress during tapping. Appl Ergon 2013, 44:969-976.
- [34]Onyebeke LC, Young JG, Trudeau MB, Dennerlein JT: Effects of forearm and palm supports on the upper extremity during computer mouse use. Appl Ergon 2014, 45:564-570.
- [35]Dai W, Zhao X, Wang Z, Yang L: Electromyographical study on muscle fatigue in repetitive forearm tasks. J Huazhong Univ Sci Technol Med Sci 2007, 27:358-361.