| Heritage Science | |
| Indoor/outdoor particulate matter concentrations and microbial load in cultural heritage collections | |
| Mihalis Lazaridis2  E. Katsivela3  I. Kopanakis2  L. Raisi3  G. Panagiaris1  | |
| [1] Department of Conservation of Antiquities and Works of Art, Technological Educational Institute of Athens, Egaleo, Athens, 12210, Greece | |
| [2] Department of Environmental Engineering, School of Environmental Engineering, Technical University of Crete, Polytechneioupolis, Chania, 73100, Crete, Greece | |
| [3] Department of Environmental and Natural Resources Engineering, Technological Educational Institute of Crete, Chania, 73133, Greece | |
| 关键词: Museums and library; Indoor air; Bioaerosols; Particulate matter; | |
| Others : 1234058 DOI : 10.1186/s40494-015-0063-0 |
|
| received in 2015-05-07, accepted in 2015-11-03, 发布年份 2015 | |
PDF
|
|
【 摘 要 】
Background
Particulate matter, microorganisms in air and environmental conditions present a potential risk to museum collections. There are also limited studies of simultaneous measurements of airborne particles and microorganisms inside museums and the effects of seasonal variations. Therefore, extensive indoor/outdoor measurements of particulate matter mass/number concentrations and viable, cultivable microbial load were performed in two museums and a library in Greece for a period of 2 years at selected time intervals. The culture heritage collections are located at coastal (Historical Museum of Crete in Heraklion), urban (Criminology Museum of the University of Athens) and mountainous (Neophytos Doukas Library in Zagori) environments and their collections consist mainly of organic materials. Measurements of inhalable particulate mass (PM 10 , PM 2.5 , PM 1 ) and viable, cultivable airborne microorganism concentrations (heterotrophic bacteria, cellulose metabolizing bacteria, acid producing bacteria and mesophilic fungi) in air were performed.
Results and conclusions
The indoor PM 10and microbial concentrations were higher than the outdoor levels showing the influence of the indoor sources, such as the presence of people and indoor activities, as well as, anthropogenic outdoor sources, and natural emissions. Elevated PM 1particle number concentrations were also encountered in the Historical Museum of Crete in Heraklion and the Criminology Museum of the University of Athens due to the high anthropogenic emissions of the urban areas. The lowest concentrations of viable, cultivable airborne microorganisms were measured in the Historical Museum of Crete at the coastal site, which encounters also well controlled microclimatic conditions. In comparison to the other two naturally ventilated sites, the highest concentrations of viable, cultivable airborne fungi were measured in the Neophytos Doukas Library at the mountainous site, whereas the highest concentrations of viable, cultivable airborne heterotrophic bacteria were measured in the Criminology Museum of the University of Athens at an urban site, where mummified tissues and dry specimens are exhibited. The closed showcases of the two museums and the library could only protect the exhibits from viable, cultivable airborne fungi, but not from specific categories of bacteria. Acid producing bacteria in the Historical Museum of Crete, cellulose metabolizing bacteria in the Neophytos Doukas Library, and opportunistic pathogenic heterotrophic bacteria in the Criminology Museum of the University of Athens showed to be enriched inside the closed showcases.
【 授权许可】
2015 Lazaridis et al.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20151127021345960.pdf | 2157KB | ||
| Fig.9. | 39KB | Image | |
| Fig.8. | 107KB | Image | |
| Fig.7. | 32KB | Image | |
| Fig.6. | 40KB | Image | |
| Fig.5. | 50KB | Image | |
| Fig.4. | 36KB | Image | |
| Fig.3. | 36KB | Image | |
| Fig.2. | 17KB | Image | |
| Fig.1. | 62KB | Image |
【 图 表 】
Fig.1.
Fig.2.
Fig.3.
Fig.4.
Fig.5.
Fig.6.
Fig.7.
Fig.8.
Fig.9.
【 参考文献 】
- [1]Camuffo D. Microclimate for cultural heritage. Elsevier, Amsterdam; 1998.
- [2]Gysels K, Delalieux F, Deutsch F, Van Grieken R, Camuffo D, Bernardi A, Sturaro G, Busse HJ, Wiser M. Indoor environment and conservation in the Royal Museum of Fine Arts, Antwerp, Belgium. J Cult Herit. 2004; 5:221-230.
- [3]Brimblecombe P. Review article: the composition of museum atmospheres. Atmos Environ. 1990; 24B:1-8.
- [4]Anaf W, Horemans B, Madeira TI, Carvalho ML, De Wael K, Van Grieken R. Effects of a constructional intervention on airborne and deposited particulate matter in the portuguese national tile museum, Lisbon. Environ Sci Pollut Res. 2013; 20:1849-1857.
- [5]Lopez-Aparicio S, Smolik J, Maskova L, Souckova M, Grontoft T, Ondrackova L, Stankiewicz J. Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope. Build Environ. 2011; 46:1460-1468.
- [6]Grau-Bove J, Strlic M. Fine particulate matter in indoor cultural heritage: a literature review. Herit Sci. 2013; 1:8. BioMed Central Full Text
- [7]Smolík J, L. Mašková N, Zíková L, Ondráčková L, Ondráček J. Deposition of suspended fine particulate matter in a library. Herit Sci. 2013; 1:7. BioMed Central Full Text
- [8]Brimblecombe P, Blades N, Camuffo D, Sturaro G, Valentino A, Gysels K, Van Grieken R, Busse H-J, Kim O, Ulrych U, Wieser M. The indoor environment of a modern museum building, the Sainsburt Centre for Visual Arts, Norwich, UK. Indoor Air. 1999; 9:146-164.
- [9]Gauzere C, Moletta-Denat M, Blanquart H, Ferreira S, Moularat S, Godon J-J, Robine E. Stability of airborne microbes in the Louvre Museum over time. Indoor Air. 2014; 24:29-40.
- [10]Gauzere C, Moletta-Denat M, Bousta F, Moularat S, Orial G, Ritoux S, Godon JJ, Robine E. Reliable procedure for molecular analysis of airborne microflora in three indoor environments: an office and two different museum contexts. CLEAN Soil Air Water. 2013; 41:226-234.
- [11]Worobiec A, Samek L, Krata A, Van Meel K, Krupinska B, Stefaniak EA, Karaszkiewicz P, Van Grieken R. Transport and deposition of airborne pollutants in exhibition areas located in historic buildings-study in Wawel Castle Museum in Cracow, Poland. J Cult Herit. 2010; 11:354-359.
- [12]Chatoutsidou SE, Mašková L, Ondráčková L, Ondráček J, Lazaridis M, Smolík J. Modeling of the aerosol infiltration characteristics in a cultural heritage building: Τhe Baroque Library Hall in Prague. Build Environ. 2015; 89:253-263.
- [13]Yoon YH, Brimblecombe P. Clothing as a source of fibres within museums. J Cult Herit. 2000; 1:445-454.
- [14]Yoon YH, Brimblecombe P. The distribution of soiling by coarse particulate matter in the museum environment. Indoor Air. 2001; 11:232-240.
- [15]Chalvatzaki E, Kopanakis I, Kontaksakis M, Glytsos T, Kalogerakis N, Lazaridis M. Measurements of particulate matter concentrations at a landfill site (Crete, Greece). Waste Manag. 2010; 11:2058-2064.
- [16]Leibniz Institute DSMZ—German Collection of Microorganisms and Cell Cultures, 2012. 457. Mineral Medium (Brunner). http://www. dsmz.de/microorganisms/medium/pdf/DSMZ_Medium457.pdf webcite
- [17]Leibniz Institute DSMZ—German Collection of Microorganisms and Cell Cultures, 2007. 105. Gluconobacter oxydans Medium. http://www. dsmz.de/microorganisms/medium/pdf/DSMZ_Medium105.pdf webcite
- [18]Diapouli E, Eleftheriadis K, Karanasiou AA, Vratolis S, Colbeck I, Lazaridis M. Indoor and outdoor particle number and mass concentrations in three houses in Athens. Sources, sinks and variability of aerosol parameters. Aerosol Air Qual Res. 2012; 11:632-642.
- [19]Serfozo N, Chatoutsidou SE, Lazaridis M. The effect of particle resuspension during walking activity to PM10 mass and number concentrations in an indoor microenvironment. Build Environ. 2014; 82:180-189.
- [20]Madrioli P, Caneva G, Sabbioni C. Cultural Heritage and aerobiology—methods and measurement techniques for biodeterioration monitoring. Springer Verlag, Berlin; 2004.
- [21]Ross C, de Menezes JR, Svidzinski TIE, Albino U, Andrade G. Studies on fungal and bacterial population of airconditioned environments. Braz Arch Biol Technol. 2004; 47(5):827-835.
- [22]Amann RI, Ludwig W, Schleifer KH. Phylogenetic identification and in situ detection of individual microbial cells without cultivation. Microbiol Rev. 1995; 59(1):143-169.
- [23]Després VR, Huffman JA, Burrows SM, Hoose C, Safatov AS, Buryak G, Fröhlich-Nowoisky J, Elbert W, Andreae MO, Pöschl U, Jaenicke R. Primary biological aerosol particles in the atmosphere: a review. Tellus B. 2012; 64:15598.
- [24]Fierer N, Liu Z, Rodríguez-Hernández M, Knight R, Henn M, Hernandez MT. Short-term temporal variability in airborne bacterial and fungal populations. Appl Environ Microbiol. 2008; 74(1):200-207.
- [25]Rappé MS, Giovannoni SJ. The uncultured microbial majority. Ann Rev Microbiol. 2003; 57:369-394.
- [26]Raisi L, Aleksandropoulou V, Lazaridis M, Katsivela E. Size distribution of viable, cultivable, airborne microbes and their relationship to particulate matter concentrations and meteorological conditions in a Mediterranean site. Aerobiologia. 2013; 29(2):233-248.
- [27]Skóra J, Gutarowska B, Pielech-Przybylska K, Stępień L, Pietrzak K, Piotrowska M, Pietrowski P. Assessment of microbiological contamination in the work environments of museums, archives and libraries. Aerobiologia. 2015; 31:389-401.
- [28]ISO 11799:2003 Information and documentation—documents to rage requirements for archive and library materials.
PDF